Navien boiler error codes
Navien boiler code E110: exhaust vent blocked
The NHB decided its exhaust vent is closed off, so flue gas cannot leave and it will not keep heating the house. The boiler stays off until the Reset button is pressed or power is cycled. Should the vent turn out to be damaged or disconnected rather than just blocked, leave the boiler shut down for a technician.

On this page
- Code
- E110
- Equipment
- Navien boiler
- Models
- NHB condensing heating boilers: NHB-055, NHB-080, NHB-110, NHB-150
- What to do
- Often an owner fix
What code E110 means
Navien's User's Information Manual - NHB Condensing Boilers lists E110 as exhaust vent blocked, for the NHB condensing heating boilers: NHB-055, NHB-080, NHB-110, NHB-150. The NHB shows a three digit E code on its front display with the error icon lit. Between faults the display cycles the supply water temperature and the heating system pressure.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- An air intake filter clogged with dust or lint, which Navien says will stop this boiler with this code.
- An exhaust vent that is closed off or obstructed.
What you can safely check
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E110 (the manual's first suspect is an air intake filter clogged with dust or lint, which Navien says will stop this boiler with this code). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Other Navien boiler codes
- E001
- E003
- E004
- E012
- E016
- E030
- E046
- E047
- E060
- E109
- E205
- E218
- E271
- E278
- E279
- E291
- E302
- E352
- E353
- E515
- E517
- E594
- E615
- E736
- E740
- E777
- E782
- E784
The full Navien boiler code table lists every code with its meaning, and explains how to read and clear them.