AC not turning on
Burning smells, sparking, buzzing or a breaker that trips twice mean switch off and call a licensed professional. Otherwise check the thermostat, filter, breaker and switches, and call a technician if the outdoor unit still will not start.

On this page
On the hottest day of the year, an air conditioner that will not start feels like an emergency. It rarely is a dangerous one, and often the cause is a switch, a setting or a dirty filter. This page is for an air conditioner that does not start at all. If yours runs and blows warm air, use the other tool linked below instead.
AC not turning on
For an air conditioner that does not start at all. Burning smells and a breaker that keeps tripping come first. Then the thermostat, filter, breaker and switches an owner can check, and the signs that mean a technician.
Any burning smell, smoke, sparking, loud buzzing, or standing water near the electrical equipment?
Yes, one of those
Act now
Turn it off and call a licensed professional now
Burning smells, sparking and buzzing point to an electrical fault, and the manufacturer says to shut the system off and call for service.
What to do
- If you see smoke or flames, or the smell is strong, leave the home and call 911.
- Otherwise switch the equipment off at the thermostat and leave any breaker that tripped off. Do not keep resetting it.
- Call a licensed HVAC professional or electrician now. Do not open panels or touch wiring.
- Stay out of standing water near the equipment.
No
Is the thermostat screen on, set to cool, with the target below the room temperature?
The screen was blank or the setting was wrong, and I fixed it
Keep an eye on it
Give it a few minutes, then watch it
Dead thermostat batteries or the wrong mode keep the air conditioner from ever being told to start.
What to do
- Wait a few minutes for the system to start, then feel the vents.
- If it does not start, come back and answer the next questions.
It is set correctly
Is the air filter clean?
Switch the system off at the thermostat before you pull the filter.
No, it was dirty and I replaced it
Keep an eye on it
Restart it and watch it
A clogged filter restricts airflow, which can make the system overheat or freeze and keep it from starting.
What to do
- Restore power and set the thermostat to cool.
- If you find ice on the lines or coil, turn cooling off to let it thaw and use the AC freezing up tool.
- If it still will not start, answer again from the top.
Yes, it is clean
Look at the breaker panel. Is the air conditioner's breaker tripped, or sitting between on and off?
Only if the panel is dry and easy to reach. Do not open the panel cover.
Yes, and I switched it fully off and on once
After that one reset, did the breaker trip again or the AC fail to start?
Yes, it tripped again or still will not start
Act now
Stop resetting it and call a licensed professional now
A breaker that trips again means an electrical fault in the air conditioner or its circuit, such as a shorted part or damaged wiring.
What to do
- If you see smoke or flames, or the smell is strong, leave the home and call 911.
- Otherwise switch the equipment off at the thermostat and leave any breaker that tripped off. Do not keep resetting it.
- Call a licensed HVAC professional or electrician now. Do not open panels or touch wiring.
No, the AC is running
Keep an eye on it
Watch it, and book a check
A breaker can trip once during an overload, for example on a very hot day with a dirty filter. A repeat means a fault.
What to do
- Keep the filter clean and the outdoor unit clear.
- If the breaker trips again, leave it off and call a licensed electrician or HVAC professional.
It is fully on
Is the service switch near the indoor unit on, and is the outdoor disconnect box in place and on?
Look at them only. Do not pull the disconnect out, because that is a live part.
A switch was off and I turned it on
Keep an eye on it
Restart it and watch it
A switch turned off during service, a cleaning or a storm is a common reason for a dead air conditioner.
What to do
- Wait a few minutes for the system to start.
- If it does not, or a breaker trips, call a licensed professional.
Both are on
When you set the thermostat to cool, what happens?
The indoor fan runs but the outdoor unit does not
Deal with it soon
Turn it off and call an HVAC technician
An indoor fan with a still outdoor unit points to a failed capacitor or contactor, a blown fuse, a refrigerant safety shutoff or a failed motor. All are repairs for a technician.
What to do
- Switch the thermostat off so the indoor fan is not running for nothing.
- Call a licensed HVAC technician and say the outdoor unit is not starting.
- Do not open the outdoor unit, replace a fuse yourself or touch wiring.
Nothing runs, even though the thermostat screen is on
Deal with it soon
Call an HVAC technician
With the thermostat on, the filter clean and the breaker and switches all on, a unit that shows no life has a control or wiring fault, or a safety switch has cut it off.
What to do
- Tell the technician each thing you checked, in order.
- Do not open the unit, replace a fuse or touch wiring.
- Ask what caused the shutdown, since a safety switch may have tripped because of a problem elsewhere.
Warning signs before the checks
The first question covers burning smells, smoke, sparking, loud buzzing and standing water near the electrical equipment. Carrier says to shut the system off and call for service at once if you hear buzzing, smell burning or see ice on the coils. The tool ends there with an act-now result: switch cooling off at the thermostat, leave any tripped breaker as it is, stay out of the water and call a licensed HVAC professional or electrician. Smoke or flames mean leave and call 911.
Checks that follow the manufacturer's order
- The thermostat. The screen should be on, set to cool, with the target below the room temperature. Dead batteries and the wrong mode are common.
- The filter. A clogged one restricts airflow and can make the system overheat or freeze, which keeps it from starting.
- The breaker. Carrier's steps for a tripped breaker are to switch it fully off, wait, switch it back on and give the unit time. If the AC will not start or the breaker trips again, stop and call. The tool allows one reset and no more, because repeated resets can hide a short or damaged wiring.
- The switches. Many systems have a service switch near the indoor unit and a disconnect box beside the outdoor unit. Check that both are on, and look without pulling anything out.
What the symptoms point to
If the indoor fan runs but the outdoor unit does not, the likely culprits are a failed capacitor or contactor, a blown fuse, a refrigerant safety cutoff or a dead motor. A refrigerant leak and a failed motor are both outside owner territory. If nothing runs even though the thermostat is lit, a control, wiring fault or tripped safety switch is the likely cause. Carrier warns never to fit a fuse with a higher rating than the maker specifies, so the tool does not ask you to replace one.
Why it matters for the bill
A unit that struggles on a clogged filter or a dirty condenser uses more power for less cooling. Keeping the filter fresh costs little. DOE credits regular maintenance with a heating and cooling cost reduction of 10% or more.
Worked example
Rashid's air conditioner is dead on a July afternoon. There is no smell, buzzing or water. The thermostat screen is lit and set to cool, but the filter is clogged, so he swaps it. The system still does not start. Looking at the panel, he finds the breaker sitting halfway between on and off. He flips it fully off, then on once. The unit starts and runs. He keeps an eye on it, and if the breaker had tripped a second time he would have left it off and called a licensed electrician.
Renting
Rules on who must keep cooling working vary by place and by lease. Report a dead unit in writing the same day, with the help of the renter's repair request letter, and note what you tried yourself.
Related tools
If the AC runs but blows warm air, use AC blowing but not cooling. If you see ice, use AC freezing up. For lower summer bills, see the summer bill reduction checklist.