Skip to content
WattsBack

Navien non-condensing tankless water heater error codes

Navien non-condensing tankless water heater code E003: no ignition on the npn

When a hot tap opened, the NPN tried to light its burner and never proved a flame. It gives up on that attempt and holds the code until it is reset.

Photograph of a plain white wall-mounted tankless water heater with insulated pipes below it
On this page
Code
E003
Equipment
Navien non-condensing tankless water heater
Models
NPN non-condensing series: NPN-160U, 180U, 199U, 120E, 160E, 180E, 199E
What to do
Technician repair

What code E003 means

Navien's User's Information Manual - NPN Non-Condensing Water Heaters lists E003 as no ignition on the npn, for the NPN non-condensing series: NPN-160U, 180U, 199U, 120E, 160E, 180E, 199E. On indoor NPN models the code shows on the front panel next to an error icon. Outdoor models have no panel of their own, so the code appears on the remote controller, whose light turns red.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A main gas valve to the heater left closed or partly closed.
  • A gas manifold or fuel DIP switch set for a different gas than the one piped to the heater, which an installer must correct.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E003 (the manual's first suspect is a main gas valve to the heater left closed or partly closed). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Navien non-condensing tankless water heater codes

The full Navien non-condensing tankless water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Navien, User's Information Manual - NPN Non-Condensing Water Heaters navieninc.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  4. Noritz, How to troubleshoot a tankless water heater noritz.com