Navien non-condensing tankless water heater error codes: what each one means

Navien's manual for the NPN non-condensing series: NPN-160U, 180U, 199U, 120E, 160E, 180E, 199E lists 31 codes. On indoor NPN models the code shows on the front panel next to an error icon. Outdoor models have no panel of their own, so the code appears on the remote controller, whose light turns red.

Photograph of a plain white wall-mounted tankless water heater with insulated pipes below it
On this page
Codes listed
31
Turn off and call a pro
6
Often an owner fix
1

How to read the code

Indoor NPN heaters have a small front panel with an error icon, a burner icon and a Reset button. Outdoor models are run from a wall remote instead: its LED glows green when all is well and red when the heater has a fault, and the code shows on the remote's screen.

To clear a code on an indoor unit, press Reset on the front panel. On an outdoor unit, press OK once on the remote and RST appears on its screen. Lock mode, which stops children changing the temperature, still lets you clear an error.

The Information button on indoor models cycles through the flow rate and the inlet and outlet water temperatures. Note these readings before you call: a technician can tell a lot from the flow and the two temperatures at the moment the code appeared.

This is a non-condensing heater, so several codes differ from Navien's NPE models: ignition and flame loss codes on the NPN also point at the gas type setting, and there are extra codes for the air volume control and the antifreeze heater. If a reset does not hold, Navien wants a technician to take over.

Navien non-condensing tankless water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

Navien non-condensing tankless water heater codes, from the User's Information Manual - NPN Non-Condensing Water Heaters
CodeWhat it meansWhat to do
E003No ignition on the NPN. When a hot tap opened, the NPN tried to light its burner and never proved a flame. It gives up on that attempt and holds the code until it is reset.Technician repair
E004False flame signal. The NPN control picked up a flame signal while the burner should have been off.Turn it off and call a pro
E012Flame lost on the NPN. The NPN lit its burner but then lost the flame signal partway through a draw of hot water. It closes the gas and stops heating until you reset it.Technician repair
E016Heat exchanger overheated. The NPN heat exchanger got too hot and the burner was shut off; Navien suggests leaving it off for at least half an hour before restarting.Turn it off and call a pro
E046High limit fault. The NPN overheat limit control has opened or is reading wrong, and the burner is kept off.Turn it off and call a pro
E056Modulating gas valve fault. The gas valve that raises and lowers the flame to match demand is not working properly.Turn it off and call a pro
E109Blower fault. The NPN combustion blower motor is not behaving as the control expects.Technician repair
E110Abnormal air pressure. The NPN saw air pressure outside its normal range, a sign the vent may be restricted; if the vent pipe is damaged or separated, stop using the heater.Often an owner fix
E127Air volume signal fault. The air volume control reads open, shorted, stuck at its default value or not answering at all.Technician repair
E157Air volume control fault. The system that sets how much air reaches the burner is not controlling it properly.Technician repair
E170Antifreeze heater fault. The electric heater that protects the unit from freezing reads as an open or short circuit, so freeze protection may not work.Technician repair
E407Outlet temperature sensor fault. The NPN outlet water sensor shows an open or shorted circuit.Technician repair
E421Inlet temperature sensor fault. The NPN cold water inlet sensor shows an open or shorted circuit.Technician repair
E434Water flow valve fault. The NPN valve that adjusts water flow for temperature control is not working right.Technician repair
E438Recirculation pump fault. The pump used for hot water recirculation is not running properly.Technician repair
E439Water flow sensor fault. The NPN flow sensor is sending readings the control cannot use.Technician repair
E441Second hot side sensor fault. The NPN second hot water sensor reads open or shorted.Technician repair
E445Mixing valve fault. The NPN bypass valve that blends cold into the hot outlet is not operating as it should.Technician repair
E515Control board fault. The NPN control board detected a fault in itself.Technician repair
E517Setup switch fault. The NPN DIP switches are in a combination the control will not accept.Technician repair
E593Panel key fault. One of the NPN front panel buttons is reading as faulty.Technician repair
E594Settings memory fault. The NPN EEPROM that holds its settings failed a self check.Technician repair
E615Processor memory fault. The NPN control found a fault in its input or memory handling.Technician repair
E736Linked unit communication fault. An NPN in a multi-heater cascade has lost its link to the other units.Technician repair
E740Outdoor temperature sensor fault. The outdoor temperature sensor connected to the NPN is not reading correctly.Technician repair
E760Flushing due. The NPN is reminding you that the installer should carry out routine service such as a heat exchanger flush.Technician repair
E762Vent pipe not inserted. The NPN cannot confirm that its vent pipe is fully pushed into the exhaust collar.Turn it off and call a pro
E773Gas connection fault. The NPN reports a problem with its gas connection, so it should not be run until a technician has checked it.Turn it off and call a pro
E782Panel communication fault. The NPN main board has lost contact with its control panel.Technician repair
E785Flow switch or sensor fault. The NPN flow switch or sensor is reporting abnormally.Technician repair
E786Panel connection fault. The connection between the NPN and its panel is not working properly.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Tankless water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.