Burning smells, smoke, sparking or a tripped breaker mean switch it off and call a professional. Otherwise check the thermostat, the power switches, the filter and the outdoor unit, and call a technician for clicking, silence or anything electrical.

Photograph of an outdoor heat pump unit beside a house at dusk with a warm window glowing above it
On this page

This page is for the heat pump that is simply dead: you set the thermostat, wait, and neither the indoor fan nor the outdoor unit does anything. It is not for a heat pump that runs but blows cool air, which has its own tool. Here the question is whether the system is getting the signal and the power it needs to start, and which of the answers a homeowner can safely test.

Heat pump not turning on

For a heat pump that does nothing at all. Burning smells and tripped breakers come first, then the thermostat, the power switches, the filter and the outdoor unit. Capacitors, compressors and wiring are for a licensed technician.

Any burning smell, smoke or sparking, or is the heat pump's breaker tripped?

A burning smell, smoke or sparking

Act now

Turn it off and call a licensed professional now

Burning smells, smoke and sparking point to an electrical fault that can start a fire.

What to do

  1. If you see smoke or flames, or the smell is strong, leave the home and call 911.
  2. Otherwise switch the equipment off at the thermostat and leave any breaker that tripped off. Do not keep resetting it.
  3. Call a licensed HVAC professional or electrician now. Do not open panels or touch wiring.
The breaker is tripped

Act now

Leave the breaker off and call a licensed professional

A tripped breaker on a heat pump means something drew too much current. The manufacturer says to have it checked rather than reset and restart it, because that can cause more damage.

What to do

  1. Switch the thermostat to off and leave the tripped breaker as it is. Do not keep resetting it.
  2. Call a licensed HVAC professional or electrician now. Do not open panels or touch wiring.
  3. If you see smoke or flames, or the smell is strong, leave the home and call 911.
Neither

Is the thermostat screen on, and is it set to heat or cool as the weather needs?

The screen was blank and I replaced the batteries

Keep an eye on it

Give it a few minutes, then watch it

A thermostat with dead batteries cannot call for heating or cooling, so the heat pump never gets the signal.

What to do

  1. Set the mode and a target that needs the heat pump to run, then wait several minutes.
  2. If the screen stays blank on a wired thermostat, call an HVAC technician. Do not touch its wiring.
  3. If the unit still does not start, answer again from the top.
The mode was wrong and I changed it

Keep an eye on it

Give it a few minutes, then watch it

A thermostat on off, or on the opposite mode from what the weather calls for, will not start the heat pump.

What to do

  1. Wait several minutes after the change.
  2. If nothing starts, come back and answer the next questions.
The screen is on and the mode is right

Are the indoor power switch and the outdoor disconnect both on?

Do not pull or reseat the outdoor disconnect yourself. Only look at it.

A switch was off and I turned it on

Keep an eye on it

Restart it and watch it

A switch that someone turned off during maintenance or a cleaning is an easy thing to miss.

What to do

  1. Wait several minutes for the system to start.
  2. If a breaker or the disconnect trips again, leave it off and call a licensed professional.
Both are on

Is the filter clean, are the return vents open, and is the outdoor unit clear of leaves, twigs, snow and shrubs?

Switch the system off before you pull the filter or clear anything near the outdoor unit.

No, I cleared or replaced something

Keep an eye on it

Restart it and watch it

A dirty filter or a blocked outdoor unit can make the system overheat and shut itself off.

What to do

  1. Restore power, set the thermostat and wait several minutes.
  2. Replace the filter on a regular schedule, and keep the outdoor unit clear of plants and snow.
  3. If it shuts off again, call an HVAC technician.
Yes, all clear

When the thermostat calls for heat or cool, what does the outdoor unit do?

It clicks or hums but does not start

Deal with it soon

Call a licensed HVAC technician

A click with no start often means a failed capacitor, the part that gives the motors their starting boost. Replacing it is electrical work for a technician.

What to do

  1. Switch the thermostat off so the unit is not trying to start repeatedly.
  2. Tell the technician about the clicking or humming.
  3. Do not open the unit or touch wiring.
Nothing at all, and the indoor fan does not run either

Deal with it soon

Call a licensed HVAC technician

With the switches, the thermostat and the filter all fine and no sign of life, the fault is in the controls, the wiring or the thermostat's connection to the system.

What to do

  1. Tell the technician what you checked, including that the screen was on.
  2. Do not open the unit or touch wiring.
  3. Ask whether your thermostat is made for a heat pump, since the wrong type can keep it from working.
The indoor fan runs but the outdoor unit stays silent

Deal with it soon

Call a licensed HVAC technician

An indoor fan running while the outdoor unit stays still points to a start component, a control fault or, if everything else is ruled out, the compressor. None is a homeowner job.

What to do

  1. Switch the thermostat off, so the indoor fan is not running for nothing.
  2. Call a licensed HVAC technician and say the outdoor unit is not starting.
  3. Do not open the unit or touch wiring.

Safety first, and why a tripped breaker is not a reset-and-forget

Because a heat pump is electrical equipment, the first question is about burning smells, smoke and sparking, and about whether the heat pump's breaker is tripped. Trane's advice is blunt: if the breaker has tripped, call for service, because resetting it and restarting the unit can do more damage. The tool follows that, so a tripped breaker ends in an act-now result. Leave the breaker off, switch the thermostat to off, and phone a licensed HVAC professional or electrician. With smoke or flames, leave the home and call 911.

The order of the checks

Thermostat. The screen should be on and the mode should match the weather. A blank screen on a battery thermostat usually means dead batteries. A wired thermostat that stays blank, or one that was never made for a heat pump, belongs to a technician, since Trane says wiring and compatible replacements should be installed professionally.

Power switches. Look at the indoor power switch and the outdoor disconnect. These get switched off during service and cleaning and then forgotten. Look only. Do not pull the disconnect out.

Airflow. A dirty filter, blocked return vents, or an outdoor unit buried in leaves, twigs or snow can make the system overheat and shut down. Trane suggests keeping clear space around the outdoor unit. Switch the system off before you pull a filter or clear anything near the unit.

What the symptoms mean

If the outdoor unit clicks or hums without starting, a failed capacitor is a common reason, because that part gives the motors their starting push. If the indoor fan runs while the outdoor unit sits still, the fault is a start component, a control problem or, once everything else is ruled out, the compressor. Replacing a capacitor or compressor is work for a licensed technician. Carrier's help page for heat pumps makes the same point about electrical parts and refrigerant.

A heat pump that will not start may leave you on backup resistance heat or no heat. Backup heat is expensive to run, so a quick repair matters. DOE notes that equipment older than 15 years deserves a replacement conversation when repairs repeat.

Worked example

Ingrid's heat pump goes silent on a chilly morning. No smell, no sparking, and the breaker is on. The thermostat screen is blank, so she replaces its batteries, sets heat and waits. Nothing happens. The indoor power switch is on, but the outdoor disconnect handle looks fine too. She clears wet leaves from the outdoor unit, which was against a fence, and waits again. The unit clicks and does not start. The tool says call a licensed technician, switch the thermostat to off so it stops trying, and report the clicking. The tech finds the capacitor failed.

Renting

Report it in writing, with the date and what you tried. The renter's repair request letter fits this. Do not open the outdoor unit even to reset something, since the landlord's technician has to do that.

If the system runs but the house stays cold, use heat pump not heating. The furnace maintenance checklist has filter and upkeep habits, and the winter bill reduction checklist covers backup heat and settings.

Sources

  1. Trane, Heat pump not turning on (help page) trane.com
  2. Carrier, Heat pump not heating (help page) carrier.com
  3. U.S. Department of Energy, Consumer Guide to Home Heating and Cooling energy.gov