Skip to content
WattsBack

A.O. Smith gas water heater error codes

A.O. Smith gas water heater 0 flashes: pilot out, no status light

The status light is dark because the pilot is not lit or the thermopile, the part the pilot flame heats to power the control, is not yet warm. With no pilot the burner cannot fire, so the tank goes cold.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Code
0 flashes
Equipment
A.O. Smith gas water heater
Models
Residential atmospheric gas water heaters with a status light gas control (75 and 100 gallon)
What to do
Often an owner fix

What code 0 flashes means

A.O. Smith's Instruction Manual - Residential Gas Water Heaters, incl. status light codes (100276479) lists 0 flashes as pilot out, no status light, for the Residential atmospheric gas water heaters with a status light gas control (75 and 100 gallon). A small status light on the gas control, beside the temperature knob, flashes a count and repeats. One flash every three seconds is normal; other counts, a steady light or no light at all point to the pilot, the thermopile or the gas control.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The pilot has gone out, or was just lit and the thermopile has not warmed up yet.
  • Gas is not reaching the heater, so the pilot cannot light.
  • The spark igniter is not lighting the pilot.
  • A weak pilot flame is not heating the thermopile enough.
  • The thermopile is worn out or its wiring connections are loose.
  • After a run of normal use, a flammable vapor incident can leave the heater unable to relight.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
  3. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 0 flashes (the manual's first suspect is the pilot has gone out, or was just lit and the thermopile has not warmed up yet). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other A.O. Smith gas water heater codes

The full A.O. Smith gas water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. A.O. Smith, Instruction Manual - Residential Gas Water Heaters, incl. status light codes (100276479) assets.aosmith.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  4. Noritz, How to troubleshoot a tankless water heater noritz.com