Bradford White heat pump water heater error codes

Bradford White heat pump water heater code 16: room too hot or too cold, or condensate drain clogged

The fault table says the air around the heater is either too warm or too cold for the compressor to run. The maintenance section also ties this number to a clogged condensate drain, which stops the heat pump and sounds an alarm while the electric elements keep the water hot.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Code
16
Equipment
Bradford White heat pump water heater
Models
AeroTherm Series hybrid electric heat pump water heaters
What to do
Often an owner fix

What code 16 means

Bradford White's Installation and Operation Manual - Hybrid Electric Heat Pump Water Heater (238-55123-00) lists 16 as room too hot or too cold, or condensate drain clogged, for the AeroTherm Series hybrid electric heat pump water heaters. Faults show as a numbered fault code on the control panel screen, from 1 up to 99, and some come with an audible alarm.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The room is outside the range the heat pump can work in; the manual names below about 37 °F and above about 120 °F.
  • The condensate drain tube is clogged with debris, so water cannot drain away.

What you can safely check

  1. Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 16 (the manual's first suspect is the room is outside the range the heat pump can work in; the manual names below about 37 °F and above about 120 °F). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Bradford White heat pump water heater codes

The full Bradford White heat pump water heater code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Bradford White, Installation and Operation Manual - Hybrid Electric Heat Pump Water Heater (238-55123-00) docs.bradfordwhite.com
  2. Bradford White, Quick Service Guide / Service Manual Supplement - Heat Pump Water Heaters AeroTherm Series (238-55219-00) docs.bradfordwhite.com