Bradford White heat pump water heater error codes: what each one means
Bradford White's manual for the AeroTherm Series hybrid electric heat pump water heaters lists 24 codes. Faults show as a numbered fault code on the control panel screen, from 1 up to 99, and some come with an audible alarm.

On this page
- Codes listed
- 24
- Turn off and call a pro
- 0
- Often an owner fix
- 3
How to read the code
The AeroTherm has a screen and buttons rather than a blinking light. When it logs a fault, the code number appears on that display. Pressing any button silences the alarm while you deal with the cause, and the screen wakes up from its blank power saving state when you touch a button.
Many codes do not leave you without hot water. If the heat pump side has a problem, such as a dirty air filter or a blocked condensate drain, the heater falls back to its electric elements, so the water stays hot but energy savings are lost until the cause is cleared. The heat pump also steps aside in very cold rooms (below about 37 °F), very hot rooms (above about 120 °F) or when the supply voltage is very low.
The codes in the 90s are hard faults: a part such as the compressor, fan, expansion valve or an element has failed and that function cannot continue. These need a technician. The heater has no power button, so turning it off for service means the breaker or a separate disconnect switch.
Two codes come up during installation. Code 10 shows if power is turned on before the tank is full, and code 6 shows when wiring gives the heater the wrong voltage. In both cases the manual says to turn the power off, fix the cause and turn it back on. Cleaning the air filter on top is the one fix an owner makes, with the power left on.
Bradford White heat pump water heater code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| 1 | Lower tank sensor fault. The lower tank temperature sensor, called T1, read outside its expected 30 to 170 °F range when the control checked it just before starting the compressor. | Technician repair |
| 3 | Lower element fault. The control switched on the lower electric heating element, but its current sensor saw no current flowing through it. | Technician repair |
| 4 | Upper element fault. The upper electric heating element was switched on, yet no current was detected through it, so the control flags it as faulty. | Technician repair |
| 5 | Main control board fault. The control found a failure of the microcontroller or a relay on its own main circuit board. | Technician repair |
| 6 | Supply voltage too low. One minute after power-up the control measured the incoming line voltage and found it below 155 volts AC, too low to run properly. | Technician repair |
| 7 | Tank over temperature. The control found that the water in the tank has overheated and reports it as a fault. | Technician repair |
| 8 | Fan fault. The fan that pulls room air across the heat pump coil is not running as it should, and its rotor may be locked. | Technician repair |
| 9 | Compressor fault. The control told the compressor to run, but its current sensor picked up no current, so the compressor is treated as failed. | Technician repair |
| 10 | Superheat fault. The control spotted a problem in the superheat stage of the refrigerant cycle, which can mean the heat pump is low on refrigerant. The same number also appears if the heater is switched on before its tank has been filled. | Technician repair |
| 11 | Airflow restriction, dirty air filter. The coil inside the heat pump is running colder than the room air around it, which tells the control that airflow is restricted, usually by a dirty air filter. The heater switches to electric only heating until the filter is cleaned and the alarm is reset. | Often an owner fix |
| 12 | Evaporator outlet sensor fault. The T3b sensor that reads the temperature leaving the evaporator coil looks shorted or open to the control. | Technician repair |
| 13 | Evaporator inlet sensor fault. The T3a sensor at the evaporator coil inlet is reading as nearly shorted or open circuit. | Technician repair |
| 14 | Compressor outlet sensor fault. The T4 sensor on the compressor outlet gives a reading the control treats as a short or an open circuit. | Technician repair |
| 15 | Room air sensor fault. The T5 sensor that measures the temperature of the surrounding air is reading shorted or open. | Technician repair |
| 16 | Room too hot or too cold, or condensate drain clogged. The fault table says the air around the heater is either too warm or too cold for the compressor to run. The maintenance section also ties this number to a clogged condensate drain, which stops the heat pump and sounds an alarm while the electric elements keep the water hot. | Often an owner fix |
| 17 | Compressor too hot. The compressor's temperature has climbed too high, so the control reports a fault and stops it. | Technician repair |
| 92 | Heating relay fault. The control detected a fault in the relay that switches the electric heating elements on and off. | Technician repair |
| 93 | Element hard fault. A heating element has failed outright and the heater cannot continue that mode of operation until it is repaired. | Technician repair |
| 94 | Condensate drain blocked. A sensor at the condensate drain port is sitting in water because the port is blocked. The heater will only heat with its electric elements until the port is cleared and the sensor is dry again. | Often an owner fix |
| 95 | Expansion valve hard fault. The EEV, the electronic expansion valve that meters refrigerant into the coil, has failed and the heat pump cannot continue. | Technician repair |
| 96 | Superheat hard fault. A superheat problem in the refrigerant cycle has become a hard fault, and the heat pump stops for good until it is serviced. | Technician repair |
| 97 | Compressor hard fault. The compressor has failed outright and the heat pump cannot run until a technician deals with it. | Technician repair |
| 98 | Fan hard fault. The fan is not working at all, so the heat pump cannot move air across its coil and stops running. | Technician repair |
| 99 | Upper tank sensor fault. The upper tank temperature sensor, T2, failed the range check of 30 to 170 °F that runs just before the compressor starts. | Technician repair |
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Bradford White, Installation and Operation Manual - Hybrid Electric Heat Pump Water Heater (238-55123-00) docs.bradfordwhite.com