Carrier 59SC5 gas furnace error codes
Carrier 59SC5 gas furnace code 14: ignition lockout
On the 59SC5 control, code 14 means only an ignition lockout: the burners failed to light and prove flame after four tries in a row, so the control stopped trying. It starts over by itself after three hours, or when power is cycled.

On this page
- Code
- 14
- Equipment
- Carrier 59SC5 gas furnace
- Models
- 59SC5A (59SC5) single-stage multipoise condensing gas furnaces
- What to do
- Technician repair
What code 14 means
Carrier's 59SC5 Single Stage 4-Way Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC5A-11SI) lists 14 as ignition lockout, for the 59SC5A (59SC5) single-stage multipoise condensing gas furnaces. An amber status light on the control board, seen through a small window in the blower door, flashes a two-digit code: the count of short flashes is the first digit and the count of long flashes is the second.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The gas valve switch or the manual gas shut-off is turned off.
- Oxide or dirt on the flame sensor, so it cannot detect the flame.
- Low gas pressure coming into the furnace.
- The green and yellow ground wire is not attached to the cabinet, or the flame sensor is touching metal.
- A failed hot surface igniter, or flame that does not carry across all burners.
What you can safely check
- Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 14 (the manual's first suspect is the gas valve switch or the manual gas shut-off is turned off). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Carrier codes
Other Carrier 59SC5 gas furnace codes
The full Carrier 59SC5 gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Carrier, 59SC5 Single Stage 4-Way Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC5A-11SI) shareddocs.com
- Carrier, Furnace not turning on (help page) carrier.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com