Rheem gas water heater error codes
Rheem gas water heater Four flashes: thermal cutoff tripped
The thermal cutoff, an overheat safety in the gas control's temperature probe, has opened. The heater locks out and will not heat until a technician finds out why it tripped.

On this page
- Code
- Four flashes
- Equipment
- Rheem gas water heater
- Models
- 38, 40 and 50 gallon FVIR gas water heaters with flue damper and electronic control
- What to do
- Turn it off and call a pro
What code Four flashes means
Rheem's Use & Care Manual: Residential Gas FVIR Water Heaters with Damper and Electronic Control (38, 40 and 50 gallon) lists Four flashes as thermal cutoff tripped, for the 38, 40 and 50 gallon FVIR gas water heaters with flue damper and electronic control. A small status light on the gas control (the box with the temperature dial) blinks a pattern, then pauses for about three seconds and repeats. Some codes are a single count; others are two counts, such as six blinks followed by one.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A fault in the thermal well, the probe that reads tank temperature for the gas control.
- The gas control itself is faulty.
- The tank is not completely full of water.
What you can safely check
- Check the water supply valves. Make sure the cold water valve to the heater is fully open and that the home has water pressure at other taps. A partly closed valve starves the heater of water.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code Four flashes (the manual's first suspect is a fault in the thermal well, the probe that reads tank temperature for the gas control). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Rheem codes
Other Rheem gas water heater codes
- Short flash
- Heartbeat
- One flash
- Two flashes
- Three flashes
- Five flashes
- Six-one flashes
- Six-two flashes
- Six-three flashes
- Six-four flashes
- Seven flashes
- Eight-one flashes
- Eight-two flashes
- Eight-three flashes
- Eight-four flashes
The full Rheem gas water heater code table lists every code with its meaning, and explains how to read and clear them.