Rheem gas water heater error codes: what each one means

Rheem's manual for the 38, 40 and 50 gallon FVIR gas water heaters with flue damper and electronic control lists 16 codes. A small status light on the gas control (the box with the temperature dial) blinks a pattern, then pauses for about three seconds and repeats. Some codes are a single count; others are two counts, such as six blinks followed by one.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Codes listed
16
Turn off and call a pro
7
Often an owner fix
3

How to read the code

The light sits on the front of the combination gas control, next to the ON/OFF slide switch and the temperature dial. A quick blink every few seconds means the water is up to temperature, and a slow bright and dim pulse means the burner is heating. Anything else is a fault pattern: count the blinks before the three second pause, and for the two part codes count both groups.

The control tries to light the pilot and burner three times. If none of those tries works, it stops and holds a lockout, and the status light shows why. Rheem points owners to the LED code chart at that point rather than to repeated restarts.

This model has a motorized flue damper on top that must open before the burner fires, so several codes are about the damper switch. The heater will not run if the damper wiring is unplugged or the damper is taken off, and the manual says the damper, gas control, burner and vent parts are for a qualified service person only.

For a vapor lockout, Rheem's fix starts with removing whatever gave off the fumes and then resetting with the ON/OFF switch on the gas control. The heater also has a combustion shut off device that trips on flammable vapors or blocked air openings at the base; if that trips, the manual says to call a technician.

Rheem gas water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

Rheem gas water heater codes, from the Use & Care Manual: Residential Gas FVIR Water Heaters with Damper and Electronic Control (38, 40 and 50 gallon)
CodeWhat it meansWhat to do
Short flashStandby, water at set temperature. One short blink every four seconds is normal: the tank has reached the dial setting and there is no fault.Often an owner fix
HeartbeatHeating, no fault. A light that pulses bright then dim means the burner is on because the water is below the setting. Nothing is wrong.Often an owner fix
One flashWeak flame signal. The control still runs the heater, but the signal it uses to prove the pilot flame is weak. Left alone, a weak signal can turn into a failed lighting lockout.Technician repair
Two flashesFlue damper switch stuck closed. The control expected the flue damper switch to be open but found it closed, so it locks the heater out and will not light the burner.Turn it off and call a pro
Three flashesFlue damper switch stuck open. The flue damper switch reads open when the control needs it closed, so the heater goes into lockout and the burner stays off.Turn it off and call a pro
Four flashesThermal cutoff tripped. The thermal cutoff, an overheat safety in the gas control's temperature probe, has opened. The heater locks out and will not heat until a technician finds out why it tripped.Turn it off and call a pro
Five flashesGas valve did not open. The control called for gas but no flame was sensed because the pilot or main burner valve did not open. The heater is locked out and the manual's fix is a new gas control.Turn it off and call a pro
Six-one flashesHeater failed to light. The heater went through its lighting tries without proving a pilot flame and is now in lockout. The burner will not try again until the cause is fixed and the control is reset.Technician repair
Six-two flashesFlue damper switch opened. The damper switch opened when the control did not expect it to, so the heater shuts down and holds a lockout.Technician repair
Six-three flashesFlame lost. The pilot flame went out after it had been lit, and the control locked the heater out. A starved air supply and a dirty or damaged pilot are the usual reasons the manual gives.Often an owner fix
Six-four flashesFlame sensed out of sequence. The control sensed flame at a time when the gas valve should have been shut, which points to a valve stuck open. It locks out, and Rheem's fix is to replace the gas control.Turn it off and call a pro
Seven flashesFlammable vapors detected. The vapor sensor near the base picked up fumes from gasoline or another flammable liquid, so the heater shut down and locked out. It stays off until the fumes are gone and the gas control is reset.Turn it off and call a pro
Eight-one flashesVapor sensor fault. The control found a problem with the flammable vapor sensor itself, not with fumes in the room, and locks the heater out.Technician repair
Eight-two flashesEnergy cutoff fault. The control found a fault in the energy cutoff circuit, part of the overheat protection in the thermal well. The heater locks out until it is repaired.Technician repair
Eight-three flashesElectronics fault. The gas control found a fault in its own electronic circuit and locked the heater out.Technician repair
Eight-four flashesGas control fault. The control reports a fault with the gas control itself and holds the heater in lockout. Sometimes it only needs a power cycle; if it returns, the control is damaged.Turn it off and call a pro

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables