Trane UH1 gas furnace 2 flashes: lockout after failed ignition

The control used up its tries to light the burners, or restarted too many times after losing the flame, and shut the gas valve and locked out. It stays locked out until the power is cycled off and on twice within 30 seconds.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
2 flashes
Equipment
Trane UH1 gas furnace
Models
*UH1 and *DH1 condensing furnaces (model starts with A or T)
What to do
Technician repair

What code 2 flashes means

Trane's Installer's Guide, incl. Integrated Furnace Control error flash codes (18-CD29D1-14-EN) lists 2 flashes as lockout after failed ignition, for the *UH1 and *DH1 condensing furnaces (model starts with A or T). A single LED on the integrated furnace control flashes slowly or quickly in normal use and blinks a count of 2 to 9 flashes when it has found a fault.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The burners did not light, or the flame sensor did not confirm flame, within the trial period.
  • The flame went out during heating and the control could not relight it.
  • Gas stopped reaching the furnace during a heating cycle.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 2 flashes (the manual's first suspect is the burners did not light, or the flame sensor did not confirm flame, within the trial period). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Trane UH1 gas furnace codes

The full Trane UH1 gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Trane / American Standard, Installer's Guide, incl. Integrated Furnace Control error flash codes (18-CD29D1-14-EN) trane.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov