Trane UH1 gas furnace error codes
Trane UH1 gas furnace 3 flashes: draft pressure error
The pressure switch did not see the draft it expects from the inducer (the exhaust fan), so the gas valve stays closed and the furnace will not run until the draft is right.

On this page
- Code
- 3 flashes
- Equipment
- Trane UH1 gas furnace
- Models
- *UH1 and *DH1 condensing furnaces (model starts with A or T)
- What to do
- Turn it off and call a pro
What code 3 flashes means
Trane's Installer's Guide, incl. Integrated Furnace Control error flash codes (18-CD29D1-14-EN) lists 3 flashes as draft pressure error, for the *UH1 and *DH1 condensing furnaces (model starts with A or T). A single LED on the integrated furnace control flashes slowly or quickly in normal use and blinks a count of 2 to 9 flashes when it has found a fault.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A blocked vent or flue, or very strong wind (over about 40 mph) pushing against the exhaust.
- A blocked condensate drain, from debris, poor draining or frozen condensate, letting water collect in the heat exchanger.
- The inducer has failed or is not building enough pressure.
- The pressure switch itself is faulty.
What you can safely check
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 3 flashes (the manual's first suspect is a blocked vent or flue, or very strong wind (over about 40 mph) pushing against the exhaust). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Trane codes
Other Trane UH1 gas furnace codes
- Slow flash
- Fast flash
- Continuous on
- Continuous off
- 2 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 8 flashes
- 9 flashes
The full Trane UH1 gas furnace code table lists every code with its meaning, and explains how to read and clear them.