Trane UH1 gas furnace error codes
Trane UH1 gas furnace 4 flashes: high limit open
The high limit, a safety switch that closes the gas valve when the furnace overheats, has opened. The burners stay off while it is open.

On this page
- Code
- 4 flashes
- Equipment
- Trane UH1 gas furnace
- Models
- *UH1 and *DH1 condensing furnaces (model starts with A or T)
- What to do
- Turn it off and call a pro
What code 4 flashes means
Trane's Installer's Guide, incl. Integrated Furnace Control error flash codes (18-CD29D1-14-EN) lists 4 flashes as high limit open, for the *UH1 and *DH1 condensing furnaces (model starts with A or T). A single LED on the integrated furnace control flashes slowly or quickly in normal use and blinks a count of 2 to 9 flashes when it has found a fault.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Too little air moving through the furnace, such as a blocked return, lets it overheat.
- A faulty limit switch, which the manual says must be replaced.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 4 flashes (the manual's first suspect is too little air moving through the furnace, such as a blocked return, lets it overheat). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Trane codes
Other Trane UH1 gas furnace codes
- Slow flash
- Fast flash
- Continuous on
- Continuous off
- 2 flashes
- 3 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 8 flashes
- 9 flashes
The full Trane UH1 gas furnace code table lists every code with its meaning, and explains how to read and clear them.