Skip to content
WattsBack

Trane UH1 gas furnace error codes: what each one means

Trane's manual for the *UH1 and *DH1 condensing furnaces (model starts with A or T) lists 12 codes. A single LED on the integrated furnace control flashes slowly or quickly in normal use and blinks a count of 2 to 9 flashes when it has found a fault.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Codes listed
12
Turn off and call a pro
4
Often an owner fix
3

How to read the code

This older control has no readout, only a light. A slow, steady blink means the furnace is waiting with no call for heat, and a fast blink means it is heating. A light that is on solid means the control board itself needs replacing, and a light that is off means the board has no power. Any other pattern is a group of flashes followed by a pause: count the flashes in one group and look up that number.

When the control locks out it stays locked out until it is reset. The manual's method is to switch the power off, on, off and on again within 30 seconds, either at the furnace's power switch or at the thermostat. If the four steps take longer than 30 seconds the reset does not take.

These furnaces also have a burner box limit with a manual reset button. The manual says it trips on excess heat and shuts off all gas. If the vent and combustion air pipes outside are blocked, clear the blockage first; if they are clear, the manual says a qualified servicer must reset it.

The blower door has a switch that cuts power to the blower and gas valve when the door comes off, and the furnace must not run with the door open or loose. If anything seems wrong with gas, power or the furnace itself, the owner's instructions say to close the manual gas valve on the supply pipe first, then turn off the power, and call the service agency.

Trane UH1 gas furnace code table

Codes with a link have their own page with causes and the checks that fit that code.

Trane UH1 gas furnace codes, from the Installer's Guide, incl. Integrated Furnace Control error flash codes (18-CD29D1-14-EN)
CodeWhat it meansWhat to do
Slow flashStandby. A normal pattern: the control has power and is waiting, with no call for heat.Often an owner fix
Fast flashHeating. A normal pattern: the thermostat is calling for heat and the furnace is working on it.Often an owner fix
Continuous onControl board failed. The LED stays lit without blinking, which the manual says means the integrated furnace control must be replaced.Technician repair
Continuous offNo power to the control. The LED is dark, so the control is not getting power and the furnace cannot run at all.Often an owner fix
2 flashesLockout after failed ignition. The control used up its tries to light the burners, or restarted too many times after losing the flame, and shut the gas valve and locked out. It stays locked out until the power is cycled off and on twice within 30 seconds.Technician repair
3 flashesDraft pressure error. The pressure switch did not see the draft it expects from the inducer (the exhaust fan), so the gas valve stays closed and the furnace will not run until the draft is right.Turn it off and call a pro
4 flashesHigh limit open. The high limit, a safety switch that closes the gas valve when the furnace overheats, has opened. The burners stay off while it is open.Turn it off and call a pro
5 flashesFlame with no call for heat. The control senses a flame at a time when there should be none, which points to a gas valve problem.Turn it off and call a pro
6 flashesReversed power or poor ground. The 115 volt supply is wired backwards or the furnace is poorly grounded, and the control will not run normally.Technician repair
7 flashesGas valve circuit error. The control found a fault in the circuit that drives the gas valve and keeps the burner off.Turn it off and call a pro
8 flashesWeak flame signal. The flame sensor signal is low, a warning that the furnace may soon fail to prove flame and lock out.Technician repair
9 flashesIgniter circuit or grounding. The control points to the igniter circuit, or to too much voltage between line neutral and the 24 volt common, which usually means a grounding problem.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. Trane / American Standard, Installer's Guide, incl. Integrated Furnace Control error flash codes (18-CD29D1-14-EN) trane.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. Sears Home Services, Water heater problems and troubleshooting searshomeservices.com
  5. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  6. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov