A.O. Smith power vent gas water heater error codes
A.O. Smith power vent gas water heater code 4: pressure switch did not close
The air pressure switch, which proves the blower is moving exhaust through the vent, stayed open more than five seconds after the blower started. The burner will not light, and the blower may keep running.

On this page
- Code
- 4
- Equipment
- A.O. Smith power vent gas water heater
- Models
- Residential power direct vent gas water heaters, 40, 50 and 75 gallon models
- What to do
- Turn it off and call a pro
What code 4 means
A.O. Smith's Instruction Manual - Residential Gas Water Heaters, Power Direct Vented Models, incl. error codes (185884-001) lists 4 as pressure switch did not close, for the Residential power direct vent gas water heaters, 40, 50 and 75 gallon models. The gas control valve on the front of the tank signals a fault with its LED lights. The manual numbers the faults 1 to 16 and pictures the LED pattern for each one in its troubleshooting chart.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Something is blocking the vent pipe or the intake air pipe.
- The small sensing tube to the pressure switch is loose, kinked or damaged.
- The vent or intake pipe is the wrong size for this heater.
- The vent or intake run has more elbows or more length than the manual allows.
What you can safely check
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 4 (the manual's first suspect is something is blocking the vent pipe or the intake air pipe). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related A.O. Smith codes
Other A.O. Smith power vent gas water heater codes
The full A.O. Smith power vent gas water heater code table lists every code with its meaning, and explains how to read and clear them.