Skip to content
WattsBack

A.O. Smith power vent gas water heater error codes: what each one means

A.O. Smith's manual for the Residential power direct vent gas water heaters, 40, 50 and 75 gallon models lists 16 codes. The gas control valve on the front of the tank signals a fault with its LED lights. The manual numbers the faults 1 to 16 and pictures the LED pattern for each one in its troubleshooting chart.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Codes listed
16
Turn off and call a pro
7
Often an owner fix
1

How to read the code

This heater plugs into a 120 volt outlet, uses a blower to push exhaust out through plastic vent pipe, and lights the burner with a hot surface igniter. Because the control checks the outlet itself, a wall outlet without a good ground or with reversed wiring will bring up a code before anything else goes wrong.

The front of the gas control has COOLER and HOTTER buttons and a row of temperature lights. The lights sleep to stop tampering: hold both buttons for one second to wake them, then press and release one button per step. Those same lights are where the control shows its LED status when there is a fault.

After three failed tries to light, the control locks out for an hour. Turning the power off and back on resets it sooner. For the self test codes 7 through 13, the manual's first step is to switch the power off for 10 to 20 seconds and back on; if the code will not clear or keeps coming back, the gas control has to be replaced.

A flammable vapor sensor near the base shuts the heater down if it senses fumes from gasoline, paint, thinners and similar products. Cleaning solvents or moisture on that sensor can also trip it, so keep it dry and keep such products stored well away from the heater.

A.O. Smith power vent gas water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

A.O. Smith power vent gas water heater codes, from the Instruction Manual - Residential Gas Water Heaters, Power Direct Vented Models, incl. error codes (185884-001)
CodeWhat it meansWhat to do
1No earth ground. The gas control found little or no earth ground on its power supply and will not run the heater until that is fixed.Technician repair
2Reversed polarity. The control found the hot and neutral sides of its 120 volt supply swapped, and it will not run the heater that way.Technician repair
3Pressure switch closed too early. The air pressure switch stayed closed for more than five seconds after a heating cycle started, before the blower had proved airflow. The blower may not start.Technician repair
4Pressure switch did not close. The air pressure switch, which proves the blower is moving exhaust through the vent, stayed open more than five seconds after the blower started. The burner will not light, and the blower may keep running.Turn it off and call a pro
5Igniter circuit open. The gas control found the hot surface igniter circuit open, so it cannot light the burner.Technician repair
6Ignition failure, one hour lockout. The burner failed to light or hold a flame on all three tries. The gas control locks the heater out for one hour, or until the power is switched off and on.Technician repair
7Gas control self test fault. Code 7 is one of three codes the manual groups together: the gas control's self test found a problem in its gas valve driver, its processor or another internal circuit.Turn it off and call a pro
8Gas control self test fault. Code 8 shares a single entry with codes 7 and 9 in the manual and points to an internal fault in the gas control found by its own self check.Turn it off and call a pro
9Gas control self test fault. Code 9 is the third of the internal circuit codes. The control's self check found trouble with the valve driver, the microprocessor or other circuits.Turn it off and call a pro
10Flame out of sequence. The control sensed a main burner flame at a point in the cycle when there should be none.Turn it off and call a pro
11Overheat cutoff tripped. The tank water went above 195 degrees F and tripped the energy cut off, the high temperature safety, so the burner is shut down.Turn it off and call a pro
12Temperature button stuck. The control's self check thinks one or both of the COOLER and HOTTER buttons are held down. It flags the fault because a stuck button could change the water temperature setting.Often an owner fix
13Tank temperature sensor fault. The water temperature sensor in the gas control's immersion probe reads open or shorted, so the control cannot tell how hot the tank is.Technician repair
14Flammable vapor sensor fault. The control's self check found the flammable vapor sensor circuit open or shorted, and the heater will not run.Technician repair
15Flammable vapors detected. The flammable vapor sensor near the base picked up fumes, and the heater shuts down and will not run. Treat it as a possible gas leak or fuel spill: do not touch electric switches or try to light anything.Turn it off and call a pro
16Lint, dust and oil lockout. The air pressure switch opened again and again during one heating cycle, which the manual calls a lint, dust and oil lockout. The heater locks out.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. A.O. Smith, Instruction Manual - Residential Gas Water Heaters, Power Direct Vented Models, incl. error codes (185884-001) assets.aosmith.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov