Goodman modulating gas furnace error codes

Goodman modulating gas furnace code E0: ignition lockout

The furnace failed to light after three tries in one call for heat and has locked out. It waits an hour before trying again unless reset.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
E0
Equipment
Goodman modulating gas furnace
Models
GMVM97 and GCVM97 modulating (ComfortBridge control)
What to do
Technician repair

What code E0 means

Goodman's Service Instructions - Modulating Gas Furnaces (RS6612015R8) lists E0 as ignition lockout, for the GMVM97 and GCVM97 modulating (ComfortBridge control). A row of three seven-segment LEDs on the ComfortBridge control board shows a letter and number code, such as E0 or B9. When the furnace is idle with no fault it shows IdL.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • No gas, or low gas pressure at the burners.
  • The front cover pressure switch is not closing, often from a kinked or wet hose, an unprimed or blocked drain trap, or a blocked vent pipe.
  • The hot surface igniter does not glow.
  • A dirty flame sensor, so the flame is not proven.
  • Gas pressure that drops after the burners light.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
  3. Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
  4. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  5. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E0 (the manual's first suspect is no gas, or low gas pressure at the burners). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman modulating gas furnace codes

The full Goodman modulating gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Service Instructions - Modulating Gas Furnaces (RS6612015R8) mobile.goodmanmfg.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
  4. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  5. Noritz, How to troubleshoot a tankless water heater noritz.com