Goodman modulating gas furnace error codes
Goodman modulating gas furnace code E3: primary limit open
The temperature at the primary limit got high enough to open it during heating, so the burner shuts off while the control protects the heat exchanger.

On this page
- Code
- E3
- Equipment
- Goodman modulating gas furnace
- Models
- GMVM97 and GCVM97 modulating (ComfortBridge control)
- What to do
- Turn it off and call a pro
What code E3 means
Goodman's Service Instructions - Modulating Gas Furnaces (RS6612015R8) lists E3 as primary limit open, for the GMVM97 and GCVM97 modulating (ComfortBridge control). A row of three seven-segment LEDs on the ComfortBridge control board shows a letter and number code, such as E0 or B9. When the furnace is idle with no fault it shows IdL.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Blocked filters or restrictive or undersized ductwork.
- The blower is set to the wrong speed for heating.
- Loose wiring in the limit circuit or to the blower motor.
- The limit switch is stuck open.
- Supply voltage to the blower is out of range, or the blower motor is failing.
- Gas inlet or manifold pressure out of spec.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E3 (the manual's first suspect is blocked filters or restrictive or undersized ductwork). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Goodman codes
Other Goodman modulating gas furnace codes
The full Goodman modulating gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Goodman, Service Instructions - Modulating Gas Furnaces (RS6612015R8) mobile.goodmanmfg.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com