Goodman modulating gas furnace code E6: low flame signal
After the furnace lights, the flame sensor current is very low, around 1 microamp or less. The furnace warns of it because ignition failures tend to follow.

On this page
- Code
- E6
- Equipment
- Goodman modulating gas furnace
- Models
- GMVM97 and GCVM97 modulating (ComfortBridge control)
- What to do
- Technician repair
What code E6 means
Goodman's Service Instructions - Modulating Gas Furnaces (RS6612015R8) lists E6 as low flame signal, for the GMVM97 and GCVM97 modulating (ComfortBridge control). A row of three seven-segment LEDs on the ComfortBridge control board shows a letter and number code, such as E0 or B9. When the furnace is idle with no fault it shows IdL.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- No proper ground wire from the furnace back to the breaker panel.
- A dirty, pitted or damaged flame sensor.
- A flame sensor that is out of line with the flame.
- Gas inlet or manifold pressure that does not match the rating plate.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E6 (the manual's first suspect is no proper ground wire from the furnace back to the breaker panel). That saves a diagnostic visit from starting at zero.