Carrier two-stage gas furnace code 13.1: limit circuit lockout

A limit, draft safeguard, flame rollout or blocked vent switch stayed open longer than three minutes, so gas heat is locked out. The control tries again after three hours.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
13.1
Equipment
Carrier two-stage gas furnace
Models
58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces
What to do
Turn it off and call a pro

What code 13.1 means

Carrier's 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) lists 13.1 as limit circuit lockout, for the 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces. A three-digit display on the control board shows codes like 32.2, and the status light seen through the sight glass on the blower door flashes only the major code as short then long flashes.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A dirty air filter or a restricted duct system.
  • A loose blower wheel, or a failing blower motor or capacitor.
  • Too little combustion air, which trips the rollout switch.
  • A restricted or wrongly sized vent, or strong wind.
  • A faulty switch or a bad connection.

What you can safely check

  1. Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
  2. Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
  3. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 13.1 (the manual's first suspect is a dirty air filter or a restricted duct system). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Carrier two-stage gas furnace codes

The full Carrier two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Carrier, 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) shareddocs.com
  2. Carrier, 59TP6C Two-Stage Non-Communicating Variable 25-Speed ECM Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59TP6C-03SI) shareddocs.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  5. Noritz, How to troubleshoot a tankless water heater noritz.com