Carrier two-stage gas furnace code 32.2: low-heat pressure switch open

The low-heat pressure switch failed to close, or dropped out again. After five minutes open the inducer rests for 15 minutes before a retry, and an opening soon after the gas valve comes on forces the next cycle to high heat.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
32.2
Equipment
Carrier two-stage gas furnace
Models
58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces
What to do
Turn it off and call a pro

What code 32.2 means

Carrier's 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) lists 32.2 as low-heat pressure switch open, for the 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces. A three-digit display on the control board shows codes like 32.2, and the status light seen through the sight glass on the blower door flashes only the major code as short then long flashes.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A restricted or wrongly sized vent, or strong wind.
  • Too little combustion air.
  • Pressure tubing that is disconnected or blocked.
  • A failed inducer motor or low voltage to it.
  • A faulty pressure switch, or low incoming gas pressure where a low gas pressure switch is used.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 32.2 (the manual's first suspect is a restricted or wrongly sized vent, or strong wind). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Carrier two-stage gas furnace codes

The full Carrier two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Carrier, 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) shareddocs.com
  2. Carrier, 59TP6C Two-Stage Non-Communicating Variable 25-Speed ECM Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59TP6C-03SI) shareddocs.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com
  4. Carrier, Furnace not turning on (help page) carrier.com
  5. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov