Carrier two-stage gas furnace error codes

Carrier two-stage gas furnace code 19.1: thermostat communication lost

The furnace lost its link with an InteliSense thermostat. This code only appears once the two have talked at least once, and it points at the thermostat wiring or setup.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
19.1
Equipment
Carrier two-stage gas furnace
Models
58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces
What to do
Often an owner fix

What code 19.1 means

Carrier's 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) lists 19.1 as thermostat communication lost, for the 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces. A three-digit display on the control board shows codes like 32.2, and the status light seen through the sight glass on the blower door flashes only the major code as short then long flashes.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The R and Y wires are not connected properly at the furnace control or at the thermostat.
  • The thermostat's advanced installation settings are not configured for this system.

What you can safely check

  1. Check the thermostat. Make sure it is set to the right mode (heat or cool) and a few degrees past the room temperature, and that its screen is on. A thermostat with dead batteries or a blank screen cannot call for heat.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 19.1 (the manual's first suspect is the R and Y wires are not connected properly at the furnace control or at the thermostat). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Carrier two-stage gas furnace codes

The full Carrier two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Carrier, 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) shareddocs.com
  2. Carrier, 59TP6C Two-Stage Non-Communicating Variable 25-Speed ECM Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59TP6C-03SI) shareddocs.com
  3. Carrier, Furnace not turning on (help page) carrier.com
  4. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  5. Noritz, How to troubleshoot a tankless water heater noritz.com