Carrier two-stage gas furnace error codes
Carrier two-stage gas furnace code 33.1: main limit circuit open
A limit, draft safeguard, rollout or blocked vent switch has opened and the burner is off. The blower runs at least four minutes, and after three minutes open the code becomes lockout 13.

On this page
- Code
- 33.1
- Equipment
- Carrier two-stage gas furnace
- Models
- 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces
- What to do
- Turn it off and call a pro
What code 33.1 means
Carrier's 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) lists 33.1 as main limit circuit open, for the 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces. A three-digit display on the control board shows codes like 32.2, and the status light seen through the sight glass on the blower door flashes only the major code as short then long flashes.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A dirty air filter or a restricted duct system.
- A loose blower wheel, or a failing blower motor or capacitor.
- Too little combustion air, which trips the rollout switch.
- A restricted or wrongly sized vent, or strong wind.
- A faulty switch or a bad connection.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 33.1 (the manual's first suspect is a dirty air filter or a restricted duct system). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Carrier codes
Other Carrier two-stage gas furnace codes
- 10.1
- 12.1
- 13.1
- 14.1
- 14.2
- 14.3
- 14.4
- 15.1
- 19.1
- 23.1
- 24.1
- 31.6
- 31.7
- 32.2
- 33.2
- 41.1
- 41.2
- 43.1
- 45.1
- 45.2
- 45.3
- 45.4
- 46.1
- 52.1
- 52.2
The full Carrier two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Carrier, 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) shareddocs.com
- Carrier, 59TP6C Two-Stage Non-Communicating Variable 25-Speed ECM Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59TP6C-03SI) shareddocs.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com