Carrier two-stage gas furnace error codes
Carrier two-stage gas furnace code 23.1: main pressure switch stuck closed
The main pressure switch reads closed before the inducer has run, so the furnace will not start a heating cycle. The service label lists stuck switches as 23.4 (main) and 23.5 (high-heat).

On this page
- Code
- 23.1
- Equipment
- Carrier two-stage gas furnace
- Models
- 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces
- What to do
- Technician repair
What code 23.1 means
Carrier's 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) lists 23.1 as main pressure switch stuck closed, for the 58TP0B, 58TP1B two-stage 80% furnaces and 59TP6C two-stage condensing furnaces. A three-digit display on the control board shows codes like 32.2, and the status light seen through the sight glass on the blower door flashes only the major code as short then long flashes.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A blocked pressure tube.
- A pressure switch stuck closed.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 23.1 (the manual's first suspect is a blocked pressure tube). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Carrier codes
Other Carrier two-stage gas furnace codes
- 10.1
- 12.1
- 13.1
- 14.1
- 14.2
- 14.3
- 14.4
- 15.1
- 19.1
- 24.1
- 31.6
- 31.7
- 32.2
- 33.1
- 33.2
- 41.1
- 41.2
- 43.1
- 45.1
- 45.2
- 45.3
- 45.4
- 46.1
- 52.1
- 52.2
The full Carrier two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Carrier, 58TP0B/58TP1B 80% AFUE Two-Stage 4-Way Multipoise Non-Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (58TP0B-01SI) shareddocs.com
- Carrier, 59TP6C Two-Stage Non-Communicating Variable 25-Speed ECM Multipoise Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59TP6C-03SI) shareddocs.com
- Noritz, How to troubleshoot a tankless water heater noritz.com