Goodman 80% gas furnace 3 flashes: pressure switch did not close

The inducer is running but the pressure switch never closed, so the control cannot prove the flue is drawing. The inducer keeps running and nothing else happens.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
3 flashes
Equipment
Goodman 80% gas furnace
Models
GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board)
What to do
Turn it off and call a pro

What code 3 flashes means

Goodman's Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) lists 3 flashes as pressure switch did not close, for the GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board). A red diagnostic LED on the control board blinks a number of times, pauses and repeats. A steady light means normal operation, rapid nonstop flashing means a polarity problem, and no light at all means no power.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The pressure switch hose is blocked, pinched or misconnected.
  • A blocked flue or chimney, or a weak inducer.
  • On masonry vent kit installs, the kit's manual reset limit has tripped.
  • The pressure switch is set wrong or its contacts are faulty.
  • Loose or wrongly connected wiring.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 3 flashes (the manual's first suspect is the pressure switch hose is blocked, pinched or misconnected). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman 80% gas furnace codes

The full Goodman 80% gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) mobile.goodmanmfg.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com