Goodman 80% gas furnace error codes: what each one means
Goodman's manual for the GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board) lists 11 codes. A red diagnostic LED on the control board blinks a number of times, pauses and repeats. A steady light means normal operation, rapid nonstop flashing means a polarity problem, and no light at all means no power.

On this page
- Codes listed
- 11
- Turn off and call a pro
- 4
- Often an owner fix
- 2
How to read the code
The red LED is on the integrated control module inside the blower compartment. Count the blinks between pauses: four blinks, a pause and four more blinks means code 4.
Count before you touch anything. The flash code disappears as soon as power to the board is cut, whether by the service switch or by pulling the blower door, which opens the door switch.
One flash is a lockout after three failed tries to light. The board clears it on its own after one hour. It also clears if power is turned off for a few seconds or the thermostat is turned down below room temperature for a few seconds and then set back. If the fault is still there, the furnace locks out again.
These furnaces vent through a standard flue or chimney, and some installs use a masonry vent kit with its own limit switch. Codes about the pressure switch, rollout switch or flame point at venting and burner problems that only a licensed technician should work on.
Goodman 80% gas furnace code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| Steady on | Normal operation. A steady, unblinking LED means the control sees no fault. | Often an owner fix |
| No flash | No power to the control. The LED shows nothing at all because the control board has no 115 volt or 24 volt power, or the board itself has failed. The furnace does not run. | Often an owner fix |
| 1 flash | Ignition lockout. The furnace failed to light or lost its flame three times in a row, or an auxiliary limit opened, so the control locked out. It retries on its own after one hour. | Technician repair |
| 2 flashes | Pressure switch closed too early. The pressure switch reads closed while the inducer is off, which should not happen, so the furnace will not start. | Technician repair |
| 3 flashes | Pressure switch did not close. The inducer is running but the pressure switch never closed, so the control cannot prove the flue is drawing. The inducer keeps running and nothing else happens. | Turn it off and call a pro |
| 4 flashes | Primary limit open. The main limit switch has opened because the heat exchanger got too hot. The burner stays off and the house blower runs nonstop to cool the furnace. | Turn it off and call a pro |
| 5 flashes | Flame sensed with no heat call. The control sees a flame signal when the thermostat is not asking for heat. The inducer and house blower both run and the furnace will not cycle normally. | Turn it off and call a pro |
| 6 flashes | Rollout limit open or fuse blown. Either a rollout limit near the burners has opened because flame escaped the burner area, or the 3 amp fuse on the control board has blown. The furnace does not run. | Turn it off and call a pro |
| 7 flashes | Low flame signal. The furnace still lights and heats, but the flame sensor current is low. The control flags it so the sensor and burner flame can be looked at before ignition starts to fail. | Technician repair |
| 8 flashes | Igniter circuit problem. The control found a fault in the igniter circuit, so the burners cannot light and the furnace does not run at all. | Technician repair |
| Continuous flash | Reversed polarity. The LED flashes without pause because the 115 volt or 24 volt supply is wired backwards. The inducer runs and the furnace does nothing else. | Technician repair |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Goodman, Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) mobile.goodmanmfg.com
- Carrier, Furnace not turning on (help page) carrier.com
- Noritz, How to troubleshoot a tankless water heater noritz.com
- Sears Home Services, Water heater problems and troubleshooting searshomeservices.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov