Skip to content
WattsBack

Goodman 80% gas furnace error codes

Goodman 80% gas furnace No flash: no power to the control

The LED shows nothing at all because the control board has no 115 volt or 24 volt power, or the board itself has failed. The furnace does not run.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
No flash
Equipment
Goodman 80% gas furnace
Models
GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board)
What to do
Often an owner fix

What code No flash means

Goodman's Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) lists No flash as no power to the control, for the GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board). A red diagnostic LED on the control board blinks a number of times, pauses and repeats. A steady light means normal operation, rapid nonstop flashing means a polarity problem, and no light at all means no power.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The service switch is off or the blower door switch is open.
  • A blown fuse or tripped breaker.
  • The 24 volt wires are loose or wrongly connected.
  • A short in the 115 or 24 volt circuits.
  • The control board has an internal fault.

What you can safely check

  1. Check the power switch. Furnaces, boilers and powered water heaters have a service switch on or near the unit. Make sure it is on, and that the unit is plugged in if it has a cord.
  2. Check the breaker. Look for a tripped breaker in the electrical panel and reset it once. If it trips again, leave it off and call a technician: a breaker that keeps tripping is a fault, not a nuisance.
  3. Check that the front panel is seated. A switch behind the blower door cuts power when the panel is off or loose. Make sure the panel is pushed fully home and latched; do not tape or hold the switch closed.
  4. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code No flash (the manual's first suspect is the service switch is off or the blower door switch is open). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman 80% gas furnace codes

The full Goodman 80% gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) mobile.goodmanmfg.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com
  4. Sears Home Services, Water heater problems and troubleshooting searshomeservices.com