Goodman 80% gas furnace 6 flashes: rollout limit open or fuse blown
Either a rollout limit near the burners has opened because flame escaped the burner area, or the 3 amp fuse on the control board has blown. The furnace does not run.

On this page
- Code
- 6 flashes
- Equipment
- Goodman 80% gas furnace
- Models
- GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board)
- What to do
- Turn it off and call a pro
What code 6 flashes means
Goodman's Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) lists 6 flashes as rollout limit open or fuse blown, for the GMES80, GCES80, AMES80 and ACES80 (PCBBF145 control board). A red diagnostic LED on the control board blinks a number of times, pauses and repeats. A steady light means normal operation, rapid nonstop flashing means a polarity problem, and no light at all means no power.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Flame rollout from misaligned burners, a blocked flue or air inlet, or a failed inducer.
- A misplaced orifice plate or heat exchanger shield.
- A short in the 24 volt control or safety circuits blowing the board fuse.
- Loose or wrongly connected wiring.
- A faulty rollout limit.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 6 flashes (the manual's first suspect is flame rollout from misaligned burners, a blocked flue or air inlet, or a failed inducer). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Goodman codes
Other Goodman 80% gas furnace codes
The full Goodman 80% gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Goodman, Installation Instructions for *MES80 / *CES80 Gas Furnace (IOG-2021) mobile.goodmanmfg.com
- Noritz, How to troubleshoot a tankless water heater noritz.com