Lennox gas furnace error codes
Lennox gas furnace code E274: overheat lockout
The limit switch opened again and again, or stayed open longer than three minutes, so the control shut the system down into a one hour soft lockout. It is the lockout version of E250.

On this page
- Code
- E274
- Equipment
- Lennox gas furnace
- Models
- SL280UHNV and SL280DFNV (SL280V) and EL296DFV two-stage variable speed furnaces
- What to do
- Turn it off and call a pro
What code E274 means
Lennox's Installation Instructions SL280UHNV (507649-05, 04/2024) lists E274 as overheat lockout, for the SL280UHNV and SL280DFNV (SL280V) and EL296DFV two-stage variable speed furnaces. A single seven-segment LED on the furnace's integrated control board spells out a status letter or an error code one character at a time, so code E250 shows as E, then 2, then 5, then 0.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Low airflow through the furnace.
- Gas firing rate set too high.
- A blockage in the airflow path or heat exchanger.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E274 (the manual's first suspect is low airflow through the furnace). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Lennox codes
Other Lennox gas furnace codes
- A
- C
- d
- h
- H
- dF
- U
- E105
- E110
- E111
- E112
- E113
- E114
- E115
- E116
- E117
- E120
- E124
- E125
- E126
- E131
- E180
- E200
- E201
- E202
- E203
- E204
- E205
- E206
- E207
- E223
- E224
- E225
- E226
- E227
- E228
- E229
- E240
- E241
- E250
- E252
- E270
- E271
- E272
- E273
- E275
- E276
- E290
- E291
- E292
- E294
- E295
- E310
- E311
- E312
- E313
- E331
- E334
- E347
- E348
- E349
- E370
- E400
- E401
- E402
- E403
- E404
- E405
- E406
- E407
- E408
- E409
The full Lennox gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Lennox, Installation Instructions SL280UHNV (507649-05, 04/2024) lennox.com
- Lennox, Installation Instructions SL280DFNV Dave Lennox Signature Gas Furnace (508150-02) lennox.com
- Lennox, Unit Information / Service Literature Corp 1126-L5 (revised 08/2022) lennox.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com