Navien tankless water heater error codes
Navien tankless water heater code E016: heat exchanger too hot
A temperature sensor found the heat exchanger, the coil that passes heat from the flame into your water, running hotter than its safe limit. The heater shuts the burner down to protect itself.

On this page
- Code
- E016
- Equipment
- Navien tankless water heater
- Models
- NPE-2 condensing series: NPE-180A2, 210A2, 240A2, 180S2, 210S2, 240S2
- What to do
- Turn it off and call a pro
What code E016 means
Navien's User's Information Manual - NPE Condensing Water Heaters lists E016 as heat exchanger too hot, for the NPE-2 condensing series: NPE-180A2, 210A2, 240A2, 180S2, 210S2, 240S2. The code appears as an E followed by three digits on the front panel screen, beside the combustion and error icon. On units with the optional remote controller, the remote also shows the code and its status light turns red.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A clogged cold water inlet filter where water enters the heater.
- Scale built up inside the heat exchanger, which needs to be flushed out.
What you can safely check
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Clean the cold water inlet filter. Tankless heaters and combi boilers have a small screen where cold water enters. Debris on it lowers flow and can stop the burner lighting. The manual shows how to clean it: power off, water valves closed, then remove the screen and rinse it.
- Check the water supply valves. Make sure the cold water valve to the heater is fully open and that the home has water pressure at other taps. A partly closed valve starves the heater of water.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E016 (the manual's first suspect is a clogged cold water inlet filter where water enters the heater). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Tankless water heater, no hot water troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Navien codes
Other Navien tankless water heater codes
- E003
- E004
- E012
- E030
- E031
- E046
- E047
- E060
- E109
- E110
- E407
- E421
- E432
- E434
- E438
- E439
- E441
- E445
- E515
- E517
- E593
- E594
- E615
- E736
- E740
- E760
- E762
- E773
- E782
- E785
- E788
The full Navien tankless water heater code table lists every code with its meaning, and explains how to read and clear them.