Navien tankless water heater error codes: what each one means
Navien's manual for the NPE-2 condensing series: NPE-180A2, 210A2, 240A2, 180S2, 210S2, 240S2 lists 32 codes. The code appears as an E followed by three digits on the front panel screen, beside the combustion and error icon. On units with the optional remote controller, the remote also shows the code and its status light turns red.

On this page
- Codes listed
- 32
- Turn off and call a pro
- 8
- Often an owner fix
- 1
How to read the code
On an NPE-2 heater the error appears on the front panel screen, next to the icon that also lights when the burner is firing. If your installer added the optional remote controller, look at its screen too: its small status light is green in normal use and red when the heater has logged a fault.
To clear a code, give the Back button on the panel one press. The heater keeps your temperature setting through a power cut, so a reset does not undo your settings. If the same code comes straight back, Navien's manual says to stop and call a technician or its technical support line.
The panel remembers the last ten errors. Press Menu, pick Error History, scroll with the arrow buttons and press OK to open one. Minor faults that Navien calls level 1 make the screen flash red but let the heater keep making hot water, and they clear on their own once the cause is gone.
Two codes on this heater are about upkeep rather than a broken part. A clogged air intake filter brings up E110, and Navien asks owners to have that filter cleaned every three to four months. E760 is a reminder that routine service, such as flushing scale out of the heat exchanger, is due.
Navien tankless water heater code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| E003 | Burner did not light. The heater tried to light the burner when you opened a hot tap but never saw a flame, so it stops and shows the code. | Technician repair |
| E004 | Flame sensed when none should be. The flame sensor reported a flame while the burner was meant to be off, a safety fault that keeps the heater from firing. | Turn it off and call a pro |
| E012 | Flame went out during use. The burner lit, but the flame sensor lost sight of the flame while hot water was running. The heater shuts the gas off and stops heating until the code is cleared. | Technician repair |
| E016 | Heat exchanger too hot. A temperature sensor found the heat exchanger, the coil that passes heat from the flame into your water, running hotter than its safe limit. The heater shuts the burner down to protect itself. | Turn it off and call a pro |
| E030 | Exhaust running too hot. The flue gas leaving the heater went past about 149 °F (65 °C). The heater stops the burner as soon as it sees that temperature. | Turn it off and call a pro |
| E031 | Burner too hot. The burner area itself overheated, so the heater shuts down; the manual sends this one straight to Navien technical support. | Turn it off and call a pro |
| E046 | Limit control fault. The high limit, the safety that cuts the burner if the unit gets too hot, has tripped or is not reading right. A technician needs to find out why. | Turn it off and call a pro |
| E047 | Exhaust temperature sensor fault. The sensor that watches flue gas temperature reads as an open or shorted circuit, so the control cannot trust its exhaust reading. | Technician repair |
| E060 | Dual venturi fault. The dual venturi, the part that mixes gas and air in two stages for low and high fire, is not working as expected. | Technician repair |
| E109 | Combustion fan fault. The fan that pushes air through the burner and out the vent is not running as the control expects. | Technician repair |
| E110 | Air pressure out of range. The heater measured abnormal air pressure through the burner and vent, which usually means air cannot get in or exhaust cannot get out freely. It stops firing until the code is cleared. If any vent pipe looks cracked, loose or pulled apart, do not use the heater again until a technician has repaired it. | Often an owner fix |
| E407 | Hot water outlet sensor fault. The sensor that reads the temperature of water leaving the heater shows an open or shorted circuit. | Technician repair |
| E421 | Cold inlet sensor 1 fault. The first sensor on the incoming cold water line reads open or shorted, so the heater cannot judge how much to heat. | Technician repair |
| E432 | Cold inlet sensor 2 fault. The second cold water inlet temperature sensor shows a broken or shorted circuit. | Technician repair |
| E434 | Water adjustment valve fault. The motorized valve that trims water flow to hold your set temperature is not responding properly. | Technician repair |
| E438 | Circulation pump fault. On a heater paired with an air handler for space heating, the circulation pump is not working as it should. | Technician repair |
| E439 | Flow sensor fault. The sensor that measures how much water is passing through the heater is giving readings the control rejects. | Technician repair |
| E441 | Hot water inlet sensor 2 fault. A second temperature sensor on the hot side reads as open or shorted. | Technician repair |
| E445 | Bypass mixing valve fault. The valve that blends some cold water into the hot outlet to steady the temperature is not operating correctly. | Technician repair |
| E515 | Circuit board fault. The main control board found a problem with itself and stops normal operation. | Technician repair |
| E517 | DIP switch setting fault. The small setup switches on the control are set in a way the heater does not accept. | Technician repair |
| E593 | Front panel button fault. A key on the front panel is reading as stuck or faulty. | Technician repair |
| E594 | Memory chip fault. The EEPROM, the chip that stores the heater's settings, has failed a check. | Technician repair |
| E615 | Input and memory fault. The control found an error in its inputs or working memory and cannot run normally. | Technician repair |
| E736 | Cascade link fault. Where several heaters are linked to share the load, this unit has lost contact with the others. | Technician repair |
| E740 | Outdoor sensor fault. With an air handler connected, the outdoor temperature sensor is not giving a usable reading. | Technician repair |
| E760 | Service reminder. A maintenance alarm saying the heater is due for flushing or other routine service by the installer. | Technician repair |
| E762 | Vent pipe not seated. A detector in the exhaust collar does not feel the vent pipe pushed in far enough, so the heater refuses to run. A loose exhaust pipe can leak flue gas, so leave the heater off until a technician refits it. | Turn it off and call a pro |
| E773 | Wrong gas type detected. The heater suspects it is burning a different gas than the one it was set up for, which leads to poor combustion. Navien warns that this can make the unit malfunction, so keep it off until the setup is checked. | Turn it off and call a pro |
| E782 | Main and panel link fault. The main control board and the front panel have stopped talking to each other. | Technician repair |
| E785 | Flow switch fault. On a heater with an air handler, the flow switch or sensor on that loop is not reporting correctly. | Technician repair |
| E788 | Gas setting mismatch. The gas type chosen on the panel DIP switch does not agree with the gas type stored in the panel itself. | Turn it off and call a pro |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Tankless water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Navien, User's Information Manual - NPE Condensing Water Heaters navieninc.com
- Navien, Installation Manual - NPE Condensing Water Heaters (NPE-2) navieninc.com
- Carrier, Furnace not turning on (help page) carrier.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com