Skip to content
WattsBack

Trane gas furnace error codes

Trane gas furnace code E04: limit, rollout or reverse airflow switch open

One of the furnace's heat safety switches has opened, so the control shuts off the gas. These switches trip when part of the furnace gets hotter than it should or air moves the wrong way.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
E04
Equipment
Trane gas furnace
Models
S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces
What to do
Turn it off and call a pro

What code E04 means

Trane's Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) lists E04 as limit, rollout or reverse airflow switch open, for the S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces. A small digital display on the integrated furnace control (IFC) shows a short status word, such as Ht1 while heating, and switches to a code starting with E when it finds a fault, for example E04 or E2.1.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The main thermal limit opened because the heat exchanger area overheated.
  • A flame rollout switch opened because flame or heat reached outside the burner area.
  • A reverse airflow switch opened (downflow models have one, others two).

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E04 (the manual's first suspect is the main thermal limit opened because the heat exchanger area overheated). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Trane gas furnace codes

The full Trane gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Trane, Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) trane.com
  2. Trane, Product Data - S8X1/S8X2 80% Furnaces, incl. error code list (22-1644-1B-EN) elibrary.tranetechnologies.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com