Trane gas furnace error codes
Trane gas furnace code E2.2: too many restarts
The furnace lit, but then kept losing its flame or its first-stage pressure switch kept opening, and after ten such restarts in one call the control locked out. It starts over by itself after 60 minutes.

On this page
- Code
- E2.2
- Equipment
- Trane gas furnace
- Models
- S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces
- What to do
- Technician repair
What code E2.2 means
Trane's Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) lists E2.2 as too many restarts, for the S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces. A small digital display on the integrated furnace control (IFC) shows a short status word, such as Ht1 while heating, and switches to a code starting with E when it finds a fault, for example E04 or E2.1.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The flame went out during heating, again and again, after it had lit properly.
- The first-stage pressure switch, which proves the inducer is moving exhaust, opened ten times.
What you can safely check
- Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E2.2 (the manual's first suspect is the flame went out during heating, again and again, after it had lit properly). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Trane codes
Other Trane gas furnace codes
The full Trane gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Trane, Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) trane.com
- Trane, Product Data - S8X1/S8X2 80% Furnaces, incl. error code list (22-1644-1B-EN) elibrary.tranetechnologies.com
- Carrier, Furnace not turning on (help page) carrier.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov