Trane gas furnace error codes: what each one means
Trane's manual for the S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces lists 26 codes. A small digital display on the integrated furnace control (IFC) shows a short status word, such as Ht1 while heating, and switches to a code starting with E when it finds a fault, for example E04 or E2.1.

On this page
- Codes listed
- 26
- Turn off and call a pro
- 5
- Often an owner fix
- 9
How to read the code
These furnaces have a three-character readout on the control board, which Trane calls the integrated furnace control. In normal use it tells you what the furnace is doing: Ht1 or Ht2 for gas heat, CL1 or CL2 for cooling, HP1 or HP2 for heat pump heating. Anything that begins with the letter E is an error code. Some codes carry a decimal, such as E2.1 or E3.2, and the digit after the point narrows down which stage or which part tripped.
Two menus on the board, reached with its Menu and Option buttons, help a technician. The Err menu shows the fault that is active right now, and the L6F menu lists the six most recent faults. Holding the Option button for five seconds in that menu clears the list, so write the codes down before anyone wipes it.
The wiring diagram lists how hard the control tries before it gives up: two extra tries to light the burners and up to ten restarts after losing an established flame. After a lockout the control starts over by itself after 60 minutes. A technician checks flame strength at test pads on the board, where 0.75 to 3 microamps is the normal range.
The S8X2 non-condensing furnace uses a control with the same error list, so these codes read the same on it. That model vents differently from the condensing S9X2, so a technician should look at the venting that matches your furnace.
Trane gas furnace code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| Ht1 | Heating on low stage. A status word, not a fault: the burners are running on the first, lower gas stage. | Often an owner fix |
| Ht2 | Heating on high stage. A status word, not a fault: the burners are on the second, higher gas stage. With a single-stage thermostat the board can show it at all times. | Often an owner fix |
| CL1 | Cooling on low stage. A status word: the furnace blower is moving air for the air conditioner's first stage. | Often an owner fix |
| CL2 | Cooling on high stage. A status word: the blower is running at the higher airflow used for second-stage cooling. | Often an owner fix |
| HP1 | Heat pump heating, low stage. A status word: an outdoor heat pump is heating on its first stage and the furnace blower moves the air. | Often an owner fix |
| HP2 | Heat pump heating, high stage. A status word: the heat pump has moved up to its second stage of heating. | Often an owner fix |
| dFt | Heat pump defrost. A status word: the outdoor heat pump is melting frost off its coil, which is a normal part of winter running. | Often an owner fix |
| COF | Fan only. A status word: the blower is running by itself because the thermostat fan is set to on. | Often an owner fix |
| E01 | Internal control failure. The furnace control board found a fault inside itself, such as a lost internal signal, and cannot run the furnace normally. | Technician repair |
| E2.1 | Ignition lockout. The control tried to light the burners, used up its retries without ever proving a flame, and locked out. It tries again on its own after an hour. | Technician repair |
| E2.2 | Too many restarts. The furnace lit, but then kept losing its flame or its first-stage pressure switch kept opening, and after ten such restarts in one call the control locked out. It starts over by itself after 60 minutes. | Technician repair |
| E2.3 | Low-stage gas valve not opening. Ten times over, the control asked the first stage of the gas valve to open and found it was not powered, so it stopped trying. | Turn it off and call a pro |
| E3.1 | Low-stage pressure switch stuck closed. The first-stage pressure switch reads as closed when it should be open, so the furnace will not start a heating cycle. | Technician repair |
| E3.2 | Low-stage pressure switch open. The first-stage pressure switch did not close, so the control cannot confirm the inducer is pulling exhaust and keeps the burners off. | Technician repair |
| E3.3 | High-stage pressure switch stuck closed. The second-stage pressure switch reads as closed at a time when it should be open. | Technician repair |
| E3.4 | High-stage pressure switch open. The second-stage pressure switch did not close when the inducer sped up for high fire, so the furnace cannot run its upper stage. | Technician repair |
| E04 | Limit, rollout or reverse airflow switch open. One of the furnace's heat safety switches has opened, so the control shuts off the gas. These switches trip when part of the furnace gets hotter than it should or air moves the wrong way. | Turn it off and call a pro |
| E05 | Flame where none should be. The flame sensor reports fire at a time when the gas valve should be shut, which points to a serious gas control problem. | Turn it off and call a pro |
| E6.1 | Reversed power polarity. The 120 volt supply to the furnace is wired backwards, so the control will not run the burner safely. | Technician repair |
| E6.2 | Poor ground. The control has found that the furnace is not properly grounded, which also upsets flame sensing. | Technician repair |
| E6.3 | Igniter circuit fault. The control could not heat the hot surface igniter, the glowing part that lights the gas, so the burners cannot light and the furnace does not heat. | Technician repair |
| E7.1 | Gas valve powered when it should be off. The control sees power on the first-stage gas valve at a time when the valve should be closed, a gas control fault. | Turn it off and call a pro |
| E08 | Weak flame signal. A warning: the flame signal is lower than it should be but still good enough, so the furnace keeps heating for now. | Technician repair |
| E09 | Inducer limit or condensate switch open. A switch near the inducer (the small exhaust fan) or the condensate switch, which watches for water backing up, has opened. The control keeps the burners off while it stays open. | Often an owner fix |
| E11 | Gas valve stage fault. The control found that a gas valve stage is powered when it should be off, or unpowered when it should be on. It treats this as a gas valve circuit fault and will not run the burner normally. | Turn it off and call a pro |
| E12 | Blown fuse. The fuse on the control board has opened, which cuts the low voltage power the thermostat and controls need. | Technician repair |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Trane, Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) trane.com
- Trane, Product Data - S8X1/S8X2 80% Furnaces, incl. error code list (22-1644-1B-EN) elibrary.tranetechnologies.com
- Noritz, How to troubleshoot a tankless water heater noritz.com
- Carrier, Furnace not turning on (help page) carrier.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov