Skip to content
WattsBack

Trane gas furnace error codes

Trane gas furnace code E6.3: igniter circuit fault

The control could not heat the hot surface igniter, the glowing part that lights the gas, so the burners cannot light and the furnace does not heat.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
E6.3
Equipment
Trane gas furnace
Models
S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces
What to do
Technician repair

What code E6.3 means

Trane's Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) lists E6.3 as igniter circuit fault, for the S9X2 two-stage condensing gas furnaces; also S8X2 two-stage 80% furnaces. A small digital display on the integrated furnace control (IFC) shows a short status word, such as Ht1 while heating, and switches to a code starting with E when it finds a fault, for example E04 or E2.1.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The igniter relay on the control board has failed.
  • The igniter itself is open, meaning burned out or disconnected.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E6.3 (the manual's first suspect is the igniter relay on the control board has failed). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Trane gas furnace codes

The full Trane gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Trane, Product Data - S9X2 Two Stage Condensing Gas Fired Furnace, incl. error code list (22-1930-1G-EN) trane.com
  2. Trane, Product Data - S8X1/S8X2 80% Furnaces, incl. error code list (22-1644-1B-EN) elibrary.tranetechnologies.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com