Rheem heat pump water heater error codes: what each one means
Rheem's manual for the Electric residential hybrid (heat pump) water heaters lists 40 codes. Codes show as text on the top display, a letter and three digits such as A108 or T131. A warning icon lights and the heater beeps when a code is active.

On this page
- Codes listed
- 40
- Turn off and call a pro
- 1
- Often an owner fix
- 8
How to read the code
When the control board logs an alarm or an alert, the fault icon on the display panel lights and the unit beeps. To see the code, press NEXT until Current Alarm appears, then use the down arrow to step through every active code. The beep can be switched off in the settings menu, but the icon still lights.
The same settings menu holds an alarm history you can scroll, and a Clear History option. Active codes are cleared with the Clear Alarm button once the cause is fixed. For the water on the floor code, holding Clear Alarm for five seconds silences it for 24 hours while you find the leak.
Many of these codes do not leave you without hot water. When the heat pump side has a fault, the heater falls back to its electric elements, which keeps the water hot but costs more to run. Codes that say the heater is disabled stop all heating.
Several codes point at things an owner can look at: the air filter on top, the condensate hose, the drain pan, and whether the tank is full. Sealed refrigerant parts are not serviced; if the compressor has failed or is leaking, the manual says the unit is replaced.
Rheem heat pump water heater code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| A004 | Compressor shutdown, discharge to suction trip. The compressor was shut down on a pressure trip between its outlet and inlet sides. The heater switches to its electric elements. | Technician repair |
| A005 | Compressor shutdown, high discharge temperature. The compressor got too hot at its outlet and was shut down as an alarm. Heating moves to the electric elements. | Technician repair |
| T005 | Compressor shutdown from low airflow. The compressor outlet ran too hot because not enough air was moving over the coil, so the heat pump stops and the heater uses its electric elements instead. Hot water continues, at a higher running cost. | Often an owner fix |
| A006 | Suction temperature too low (alarm). The coil inlet side of the compressor read too cold, so the heat pump stopped and the elements took over heating. | Technician repair |
| T006 | Suction temperature too low (alert). An alert that the compressor inlet temperature dropped too low. The heater relies on its elements for now. | Technician repair |
| A008 | Dry fire protection. The control believes there is not enough water in the tank and disables heating so the elements do not burn out in air. It usually means the tank was not filled or air is still trapped in it. | Often an owner fix |
| T009 | Compressor wiring alert. An alert that the compressor wiring may be faulty. The heat pump stops and the elements heat the water. | Technician repair |
| A009 | Compressor wiring alarm. An alarm that the compressor wiring may be at fault. Heating falls back to the electric elements. | Technician repair |
| A101 | Suction temperature sensor failure. The sensor on the compressor inlet line is reading out of range. The heat pump stops and the elements take over. | Technician repair |
| A102 | Ambient air sensor failure. The sensor that reads the room air temperature has failed, so the heater switches to element heating. | Technician repair |
| A103 | Lower tank sensor failure. The lower tank temperature sensor is not reading correctly. The heater is disabled until it is fixed. | Technician repair |
| A104 | Upper tank sensor failure. The upper tank temperature sensor has failed, and the heater stops heating. | Technician repair |
| A105 | Evaporator sensor failure. The coil (evaporator) temperature sensor is out of range. The heat pump stops and elements heat the water. | Technician repair |
| A106 | Discharge sensor failure. The compressor outlet temperature sensor is failing. Heating continues on the electric elements. | Technician repair |
| A107 | Water on the floor. The leak sensor, a rope that lies in the drain pan, is wet. The heater raises an alarm so you can look for a leak before it causes damage. | Often an owner fix |
| A108 | Condensate line blocked. The condensate sensor found water backing up in the condensate pan, so the heat pump stops and the heater switches to its electric elements until the drain is clear. | Often an owner fix |
| A125 | Lower element error or stuck relay. The lower heating element or its relay on the board has a fault, possibly a relay stuck closed. Heating is disabled. | Technician repair |
| A126 | Upper element error or stuck relay. The upper element or its relay is at fault, and the heater stops heating. | Technician repair |
| A127 | Element wiring error. The element wires are routed or connected wrong, or the board has failed. Heating is disabled. | Technician repair |
| A128 | Lower element relay will not close. The relay that powers the lower element did not close when told to. The heater is disabled. | Technician repair |
| A129 | Upper element relay will not close. The upper element relay failed to close, so the heater cannot heat. | Technician repair |
| A130 | Unit off and air is freezing. The heater is switched off and the surrounding air has dropped below freezing. Turning the unit back on lets it protect itself. | Often an owner fix |
| T131 | Clean filter reminder. A routine reminder to wash the air filter on top of the heater. It is not a fault. | Often an owner fix |
| T132 | Struggling to keep up with demand. The heater cannot heat water as fast as it is being used. | Often an owner fix |
| A120 | Shutoff valve cannot close. The optional automatic water shutoff valve did not close when commanded. | Technician repair |
| A121 | Shutoff valve cannot open. The optional shutoff valve did not open when asked to. | Technician repair |
| A122 | Shutoff valve input error. The signals coming back from the optional shutoff valve do not make sense to the control. | Technician repair |
| A123 | Shutoff valve not installed. The control is set to expect a shutoff valve that it cannot find. If no valve is fitted, the setting in the control panel should say so. | Technician repair |
| A200 | High water temperature, ECO tripped. The ECO, the overheat cutoff on the tank, has tripped because the water got too hot. The heater is disabled and needs a technician. | Turn it off and call a pro |
| T300 | Leak sensor not installed. The control cannot detect the water leak sensor it expects to find. | Technician repair |
| A502 | Clock needs setting. The built in time clock has not been set and needs programming. | Often an owner fix |
| A503 | Clock not keeping time. The time clock is not moving forward correctly. | Technician repair |
| T504 | WiFi chip communication error. The control cannot talk to its WiFi module. | Technician repair |
| A900 | Controller fault. The controller has malfunctioned and the heater is disabled. The listed repair is a new control board. | Technician repair |
| T901 | Controller fault (alert). An alert that the controller is malfunctioning. Heating is disabled until the board is replaced. | Technician repair |
| A902 | Controller fault 902. Controller malfunction number 902; the heater stops and needs a replacement control board. | Technician repair |
| A903 | Controller fault 903. Controller malfunction number 903; heating is off until the board is replaced. | Technician repair |
| A904 | Controller fault 904. Controller malfunction number 904; the board needs replacing before the heater will work. | Technician repair |
| A905 | Controller fault 905. Controller malfunction number 905; the heater is disabled pending a new control board. | Technician repair |
| A906 | Power board overheating. The sensor that protects the power board reports the controller is getting too hot. | Technician repair |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.