A.O. Smith heat pump water heater error codes: what each one means

A.O. Smith's manual for the PHPT-60 and PHPT-80 hybrid electric heat pump water heaters lists 31 codes. Faults show as a text message on the touch display on the front of the heater. The exact fault name is kept in a maintenance screen as codes E01 to E04, newest first.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Codes listed
31
Turn off and call a pro
1
Often an owner fix
4

How to read the code

The display on the User Interface Module goes dark to save power; a light touch on any button wakes it. When something fails it shows a general message, such as a heat pump fault or a powered anode fault. To see the exact fault, hold the up and down arrows together for three seconds to open the maintenance display, then step through its ten screens with the up arrow.

The first six maintenance screens show temperatures, and the last four hold the fault history. E01 is the newest fault and, if a fault is showing, the active one; E02 to E04 are older. If an older entry matches E01, the fault is repeating. The history cannot be erased, so there is always something stored, fault or not.

A.O. Smith's first step for any code is to switch the heater off at the breaker for ten seconds, switch it back on and watch for the code. Allow around eight minutes, because each start runs a dry fire check of about four minutes to make sure the tank is full before the elements are allowed on.

Keep the power on when you can. The powered anode that protects the tank only works with power, so the handbook says to drain the tank if the heater will be off for a long time. The heat pump only runs between 45 and 109 degrees F of room air, and the energy cut off reset sits behind the element cover, which is work for a technician.

A.O. Smith heat pump water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

A.O. Smith heat pump water heater codes, from the Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000)
CodeWhat it meansWhat to do
Upper Element Connect FaultUpper heating element circuit open. The control found the circuit to the upper heating element open, so that element cannot heat. Since the upper element heats the top of the tank first, losing it can leave you with no hot water.Technician repair
Lower Element Connect FaultLower heating element circuit open. The circuit to the lower heating element reads open, so the bottom element cannot heat. The heater still has the heat pump and upper element, but electric backup and recovery suffer.Technician repair
Heat Pump Connect FaultCompressor circuit open. The control sees the circuit to the heat pump compressor as open, so the heat pump cannot run. Water heating falls back on the electric elements until the fault is cleared.Technician repair
Fan Connect FaultHeat pump fan circuit open. The circuit to the fan that pulls room air over the evaporator is open. Without that fan the heat pump cannot collect heat from the air.Technician repair
Ambient Temperature Sensor Short or Open or Ad ErrorRoom air sensor fault. The sensor that reads the air entering the evaporator is shorted, open or giving a bad reading. The control relies on it to decide whether room air is in the range where the heat pump may run.Technician repair
Upper Temperature Sensor Short or Open or Ad ErrorUpper tank sensor fault. The sensor on the outer wall near the top of the tank is shorted, open or reading wrong, so the control cannot judge the temperature of the hot water you draw first.Technician repair
Lower Temperature Sensor Short or Open or Ad ErrorLower tank sensor fault. The sensor on the lower part of the tank wall reads shorted, open or out of range. The control uses it with the upper sensor to work out the average tank temperature.Technician repair
Discharge Temperature Sensor Short or Open or Ad ErrorCompressor discharge sensor fault. The sensor that measures refrigerant temperature where it leaves the compressor is shorted, open or giving a bad value, so the control loses its guard against the compressor running too hot.Technician repair
Coil Temperature Sensor Short or Open or Ad ErrorEvaporator coil sensor fault. The sensor on the evaporator coil, the finned part that collects heat from room air, reads shorted, open or out of range, and the control flags a fault.Technician repair
Low Water Level AlarmTank not full (dry fire protection). During its start up check the control found the heating elements may not be covered by water. The heater will not run while the alarm is active, which protects the elements from burning out.Often an owner fix
Heat Pump Low Pressure FaultRefrigerant pressure too low. The low pressure switch in the refrigerant circuit opened because suction pressure dropped too far. The compressor is kept off until pressure recovers.Often an owner fix
Heat Pump High Pressure FaultRefrigerant pressure too high. The high pressure switch opened because the refrigerant pressure on the compressor's output side climbed too high. The compressor will not run while the switch is open.Often an owner fix
Heat Pump High Temperature FaultCompressor running too hot. The refrigerant leaving the compressor is hotter than it should be, so the control stops the heat pump to protect the compressor.Technician repair
Main Control Board Crystal FaultControl board clock fault. The crystal, the part that keeps timing for the main control board, has failed its check.Technician repair
Main Control Board RAM FaultControl board memory fault (RAM). The main control board's working memory failed its self check.Technician repair
Main Control Board ROM FaultControl board program fault (ROM). The memory that holds the main control board's program failed its check.Technician repair
Main Control Board EEPROM FaultControl board settings memory fault. The EEPROM, where the main control board keeps stored settings, failed its check.Technician repair
Main Control Board State FaultControl board state fault. The main control board found itself in a state it should not be in and reports a board failure.Technician repair
Low Supply Voltage Fault (Low input voltage)Supply voltage low. The incoming power is below the heat pump's working range of 204 to 264 volts. The compressor stays off, but the electric elements can still heat water, so bills rise.Technician repair
High Supply Voltage FaultSupply voltage high. The incoming power is above 264 volts. The compressor will not run, though the elements still can.Technician repair
Low Supply Voltage Fault (Very low input voltage)Supply voltage very low. The supply has fallen below 184 volts, the point where the whole heater stops working.Technician repair
High Temperature Lock OutOverheat cutoff tripped. The energy cut off, a high limit switch above the upper element, tripped when the tank reached about 190 degrees F. It cuts power to the elements and the compressor and stays off until it is reset by hand.Turn it off and call a pro
Condensate Drain AlarmCondensate pump failure. The float switch in an added condensate pump opened because the pump is not clearing water. The control shuts off the heat pump so it stops making condensate, and the front display shows a heat pump fault.Often an owner fix
Power Anode Over CurrentPowered anode overcurrent. The powered anode circuit drew more current than allowed, a fault the handbook traces to the control board.Technician repair
Power Anode Max Current at Min PWMPowered anode current limit. The anode circuit hit its highest current while the control was driving it at its lowest setting, which the handbook blames on the board.Technician repair
Power Anode Offset CurrentPowered anode offset fault. The control found an offset in the anode circuit's current reading and reports the anode circuit as not working.Technician repair
Power Anode Drive Voltage LT Tank VoltageAnode drive voltage below tank voltage. The voltage the control sends to the powered anode is lower than the tank's own voltage, so the anode is not protecting the tank against corrosion.Technician repair
Power Anode ADC ErrorPowered anode reading error. The board's converter that reads the anode circuit has failed, so the anode circuit is reported as not working.Technician repair
Power Anode No Tank VoltageNo tank voltage at anode. The powered anode circuit sees no voltage from the tank, so corrosion protection is not working. The heater flags a powered anode fault.Technician repair
Power Anode No Current SenseNo anode current sensed. The control cannot sense current in the anode circuit and reports it as not working.Technician repair
Power Anode Wrong Voltage FeedbackWrong anode voltage feedback. The voltage coming back from the powered anode is not what the control expects. The anode circuit is treated as not working, and the tank loses its corrosion protection.Technician repair

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. A.O. Smith, Service Handbook - Residential Hybrid Electric Heat Pump Water Heater, incl. fault codes (321547-000) assets.aosmith.com
  2. Noritz, How to troubleshoot a tankless water heater noritz.com
  3. ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
  4. Carrier, Furnace not turning on (help page) carrier.com
  5. Sears Home Services, Water heater problems and troubleshooting searshomeservices.com