Bradford White gas water heater error codes: what each one means

Bradford White's manual for the Residential D Series flue damper gas water heaters (RG1D30T, RG1D40S) with ICON System control lists 17 codes. A green light on the electronic gas control blinks a count, rests for three seconds, then repeats. Some codes are one count, such as four blinks; others are two groups, such as six blinks and then one.

Photograph of a plain white tank water heater with copper pipes in a tidy utility closet
On this page
Codes listed
17
Turn off and call a pro
8
Often an owner fix
3

How to read the code

The light is on the ICON System gas control, the box on the front of the tank that holds the temperature knob and the power switch. One short blink every four seconds means the tank is at temperature, and a light that pulses bright then dim means the burner is heating. Any other rhythm is a status code: count the blinks before the three second rest, and on two part codes count both groups.

Most codes on this heater clear by themselves. After a damper fault the control waits two to five minutes and tries the damper again. If the pilot will not light, or goes out, the control retries and then sits out a five minute lockout before starting over. Faults with its own sensors clear about 15 seconds after the reading returns to normal.

The four blink code is different: the water got hot enough to trip the energy cut off, and the control stays locked out until it is reset. The service manual describes resetting it with the temperature knob on the gas control, then relighting by the lighting label. It also says the cause of the overheating has to be found, so a technician should look before the heater goes back into use.

This model has a motorized flue damper on top that must swing open before the pilot lights, which is why several codes are about the damper. It also carries Bradford White's Defender system, a flammable vapor sensor, a flame arrestor and a thermal switch that shut the burner down if fumes or too little combustion air cause a problem. Bradford White writes this manual for qualified service people, not for owners.

Bradford White gas water heater code table

Codes with a link have their own page with causes and the checks that fit that code.

Bradford White gas water heater codes, from the Service Manual - Residential D Series Gas Water Heaters, incl. ICON status codes (238-51637-00)
CodeWhat it meansWhat to do
No flashLight off, no power to the control. The status light is dark and not blinking at all, which means the gas control has no electrical power and cannot run the heater.Often an owner fix
One short flashStandby, water at set temperature. A single short blink every four seconds is the normal idle signal: the tank is up to the knob setting and the heater is waiting.Often an owner fix
HeartbeatHeating, no fault. A light that fades between bright and dim means the burner is on because the tank is cooler than the setting. Nothing is wrong.Often an owner fix
Short flash onceWeak pilot signal. A short blink about once a second means the pilot flame signal was weak on the last heating cycle. The heater still runs, but the pilot needs attention before it starts failing to light.Technician repair
Two flashesFlue damper circuit closed when it should be open. Before opening the flue damper, the control checks its safety circuit and found it already closed, as if the damper were stuck open. It will not light the burner, and it waits two minutes before trying the damper again.Turn it off and call a pro
Three flashesFlue damper did not open fully. The control powered the flue damper open, but the damper safety circuit did not prove it reached the fully open position within 30 seconds. The burner stays off, and the control keeps retrying the damper every few minutes.Turn it off and call a pro
Four flashesTank too hot, energy cut off tripped. The water got hotter than the energy cut off limit (about 188 °F on this control), so the control shut the pilot and burner gas off. Unlike most codes on this heater, it does not clear by itself and must be reset.Turn it off and call a pro
Five flashesPilot flame present when it should be off. The control sees a pilot flame while the pilot valve should be shut, and holds the heater off until that flame goes out.Turn it off and call a pro
Six-one flashesPilot failed to light. The igniter sparked for 90 seconds without proving a pilot flame. The control shuts the pilot gas, waits five minutes and then tries again on its own.Technician repair
Six-two flashesDamper moved while the burner was on. During a heating cycle the flue damper left its fully open position, so the control shut off the pilot and burner gas. It retries on its own after about five minutes.Turn it off and call a pro
Six-three flashesPilot flame went out. The pilot was lit but the flame was lost while the heater was running. The control tries to relight up to four times, then waits out a five minute lockout before starting again by itself.Technician repair
Six-four flashesFalse pilot flame sensed. The control saw flame out of sequence, waited for it to go out, and now shows this code while it sits out five minutes before its next try.Turn it off and call a pro
Seven flashesFlammable vapor sensor or thermal switch tripped. Part of the Defender safety system has shut the heater down: either the flammable vapor sensor near the base reacted, or the resettable thermal switch, an overheat cutoff in the combustion chamber, has opened.Turn it off and call a pro
Eight-one flashesFlammable vapor sensor out of range. The control's reading from the flammable vapor sensor is outside its allowed range, so it keeps all outputs off; the manual sends this to the sensor test.Technician repair
Eight-two flashesTemperature sensor fault. The temperature sensor in the gas control reads open or out of range, so the control turns everything off. It clears itself if the reading recovers for about 15 seconds.Technician repair
Eight-three flashesGas control electronics fault. The gas control found a fault in its own electronics and stopped running the heater. The manual's first step is to cut and restore power to reset it; if that does not work, the control is replaced.Technician repair
Eight-four flashesGas valve fault. The control detected a problem with the gas valve built into it and keeps the burner off. A technician first tries a power reset and replaces the gas control if the code returns.Turn it off and call a pro

Codes that mean turn it off

These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:

Code by code

No code showing?

If the unit is not working and shows no code at all, start with the Water heater, no hot water troubleshooter. It covers power, settings and supply problems that stop the control from running at all.

More error code tables

Sources

  1. Bradford White, Service Manual - Residential D Series Gas Water Heaters, incl. ICON status codes (238-51637-00) docs.bradfordwhite.com
  2. Carrier, Furnace not turning on (help page) carrier.com
  3. Noritz, How to troubleshoot a tankless water heater noritz.com
  4. Sears Home Services, Water heater problems and troubleshooting searshomeservices.com
  5. U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov