Goodman heat pump error codes
Goodman heat pump code E15: repeated low pressure
The system keeps tripping on low refrigerant pressure and the control has flagged it as critical, so the outdoor unit stops. The manual names a leak, low charge or a partly closed valve as typical reasons.

On this page
- Code
- E15
- Equipment
- Goodman heat pump
- Models
- GSZV9 inverter heat pump (ComfortBridge)
- What to do
- Technician repair
What code E15 means
Goodman's *SZV9 Heat Pump Installation & Service Reference (IOG-4042) lists E15 as repeated low pressure, for the GSZV9 inverter heat pump (ComfortBridge). A three-digit seven-segment display on the outdoor unit's control board shows the fault as E plus a number, such as E15. A communicating thermostat shows the same fault as a number with a short message.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A service valve that is not fully open.
- A restriction in the refrigerant lines.
- Low refrigerant charge or a refrigerant leak.
- The low pressure sensor has failed or come loose.
- The indoor blower motor is not working properly.
- A faulty expansion valve (TXV) or control board.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E15 (the manual's first suspect is a service valve that is not fully open). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Heat pump not heating troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Goodman codes
Other Goodman heat pump codes
- E12
- E13
- E17
- E18
- E19
- E20
- E21
- E22
- E23
- E24
- E25
- E26
- E27
- E28
- E29
- E30
- E31
- E32
- E34
- E35
- E36
- E37
- E38
- E39
- E40
- E41
- E42
- E43
- E44
- E45
- E46
- E47
- E48
- E49
- E50
- E51
- Eb0
- Eb9
- Ed0
- Ed1
- Ed2
- Ed3
- Ed4
The full Goodman heat pump code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Goodman, *SZV9 Heat Pump Installation & Service Reference (IOG-4042) mobile.goodmanmfg.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com