Goodman heat pump code E15: repeated low pressure

The system keeps tripping on low refrigerant pressure and the control has flagged it as critical, so the outdoor unit stops. The manual names a leak, low charge or a partly closed valve as typical reasons.

Photograph of an outdoor heat pump unit with light snow on its top beside a house in winter
On this page
Code
E15
Equipment
Goodman heat pump
Models
GSZV9 inverter heat pump (ComfortBridge)
What to do
Technician repair

What code E15 means

Goodman's *SZV9 Heat Pump Installation & Service Reference (IOG-4042) lists E15 as repeated low pressure, for the GSZV9 inverter heat pump (ComfortBridge). A three-digit seven-segment display on the outdoor unit's control board shows the fault as E plus a number, such as E15. A communicating thermostat shows the same fault as a number with a short message.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • A service valve that is not fully open.
  • A restriction in the refrigerant lines.
  • Low refrigerant charge or a refrigerant leak.
  • The low pressure sensor has failed or come loose.
  • The indoor blower motor is not working properly.
  • A faulty expansion valve (TXV) or control board.

What you can safely check

  1. Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E15 (the manual's first suspect is a service valve that is not fully open). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Heat pump not heating troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman heat pump codes

The full Goodman heat pump code table lists every code with its meaning, and explains how to read and clear them.