Skip to content
WattsBack

Goodman heat pump error codes

Goodman heat pump code E19: outdoor board or fan fault

The control keeps seeing faults with the outdoor fan motor or the outdoor control board. The outdoor unit stops running while the fault is active.

Photograph of an outdoor heat pump unit with light snow on its top beside a house in winter
On this page
Code
E19
Equipment
Goodman heat pump
Models
GSZV9 inverter heat pump (ComfortBridge)
What to do
Technician repair

What code E19 means

Goodman's *SZV9 Heat Pump Installation & Service Reference (IOG-4042) lists E19 as outdoor board or fan fault, for the GSZV9 inverter heat pump (ComfortBridge). A three-digit seven-segment display on the outdoor unit's control board shows the fault as E plus a number, such as E15. A communicating thermostat shows the same fault as a number with a short message.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Something is stopping the fan blade from turning, such as debris in the grille.
  • The outdoor fan motor is not wired to the board properly.
  • The outdoor fan is not running.
  • A faulty control board or electrical noise.

What you can safely check

  1. Clear around the outdoor unit. Keep leaves, snow and plants at least two feet away from the outdoor unit, and make sure its breaker is on.
  2. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  3. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E19 (the manual's first suspect is something is stopping the fan blade from turning, such as debris in the grille). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Heat pump not heating troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman heat pump codes

The full Goodman heat pump code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, *SZV9 Heat Pump Installation & Service Reference (IOG-4042) mobile.goodmanmfg.com
  2. U.S. Department of Energy, Energy Saver: Air Conditioner Maintenance (archived June 14, 2026) web.archive.org
  3. Noritz, How to troubleshoot a tankless water heater noritz.com