Goodman heat pump code E32: outdoor board overheating

The outdoor control board keeps running too hot and the control has flagged it as a fault. The unit stops until the board cools and conditions allow it to restart.

Photograph of an outdoor heat pump unit with light snow on its top beside a house in winter
On this page
Code
E32
Equipment
Goodman heat pump
Models
GSZV9 inverter heat pump (ComfortBridge)
What to do
Technician repair

What code E32 means

Goodman's *SZV9 Heat Pump Installation & Service Reference (IOG-4042) lists E32 as outdoor board overheating, for the GSZV9 inverter heat pump (ComfortBridge). A three-digit seven-segment display on the outdoor unit's control board shows the fault as E plus a number, such as E15. A communicating thermostat shows the same fault as a number with a short message.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Outdoor air too hot for the unit's operating range.
  • Missing or loose screws on the board's cooling bracket (2 to 4 ton units).
  • Too little thermal grease between the cooling loop and the bracket (2 to 4 ton units).
  • The outdoor fan running slow (5 ton units).
  • Little or no refrigerant flow through the board's cooling circuit, or a service valve not fully open (2 to 4 ton units).

What you can safely check

  1. Clear around the outdoor unit. Keep leaves, snow and plants at least two feet away from the outdoor unit, and make sure its breaker is on.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
  3. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E32 (the manual's first suspect is outdoor air too hot for the unit's operating range). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Heat pump not heating troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman heat pump codes

The full Goodman heat pump code table lists every code with its meaning, and explains how to read and clear them.