Goodman heat pump error codes: what each one means
Goodman's manual for the GSZV9 inverter heat pump (ComfortBridge) lists 44 codes. A three-digit seven-segment display on the outdoor unit's control board shows the fault as E plus a number, such as E15. A communicating thermostat shows the same fault as a number with a short message.

On this page
- Codes listed
- 44
- Turn off and call a pro
- 0
- Often an owner fix
- 7
How to read the code
The display is on the control board inside the outdoor unit. Its home screen (screen 0) shows the fault that is active right now. Do not open the control box to look: the manual warns that parts of the board stay charged after power is cut, and a technician waits and measures before touching it.
The board stores the six most recent faults on screen 1. A technician reaches it by holding the RECALL button for five seconds, steps through older faults with RECALL, and goes back to the home screen with LEARN. The same history is in the CoolCloud HVAC app. A fault that repeats back to back is stored no more than three times, and the list can be cleared after service.
On a communicating thermostat the code appears as a plain number with a short message, such as 15 with LOW PRESSURE C. A C at the end means critical. Some minor faults, where the control decided the unit can keep running, show only on the thermostat and never on the outdoor display.
Codes E45 to E49 are not breakdowns. They mean the unit could not start a test, pump down or charging mode because the thermostat had indoor heat on. The fix is to set the thermostat to off first.
Goodman heat pump code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| E12 | Control memory error. The outdoor control board reports a general memory error in its own electronics, and the outdoor unit may stop running until it clears. | Technician repair |
| E13 | Repeated high pressure. The system keeps tripping on high refrigerant pressure and the control has flagged it as critical. The outdoor unit stops to protect the compressor. | Technician repair |
| E15 | Repeated low pressure. The system keeps tripping on low refrigerant pressure and the control has flagged it as critical, so the outdoor unit stops. The manual names a leak, low charge or a partly closed valve as typical reasons. | Technician repair |
| E17 | Compressor fault. The control keeps seeing compressor faults and stops the outdoor unit. | Technician repair |
| E18 | Control board fault 2. The outdoor board reports an internal problem that suggests it may need replacing. | Technician repair |
| E19 | Outdoor board or fan fault. The control keeps seeing faults with the outdoor fan motor or the outdoor control board. The outdoor unit stops running while the fault is active. | Technician repair |
| E20 | Expansion valve coil open. The coil that drives the outdoor electronic expansion valve (EEV) is not connected, so the control cannot meter refrigerant. | Technician repair |
| E21 | Low discharge superheat. The system keeps showing low discharge superheat, a sign refrigerant is not being metered correctly, and the control flags a fault. | Technician repair |
| E22 | High discharge temperature. The compressor discharge keeps running too hot, and the control stops the compressor to protect it. | Technician repair |
| E23 | Discharge sensor out of range. The discharge temperature sensor is reading outside its normal range. | Technician repair |
| E24 | High pressure switch open. The high pressure safety switch is open, so the compressor is held off. | Technician repair |
| E25 | Outdoor air sensor fault. The outdoor air temperature sensor reads open or shorted. | Technician repair |
| E26 | Pressure sensor fault. The control decides the refrigerant pressure sensor is not responding the way it should. | Technician repair |
| E27 | Defrost sensor out of range. The outdoor defrost sensor is reading outside its normal range, which affects defrost control. | Technician repair |
| E28 | Outdoor coil sensor out of range. The outdoor coil temperature sensor is reading outside its normal range. | Technician repair |
| E29 | Liquid line sensor out of range. The liquid line temperature sensor is reading outside its normal range. | Technician repair |
| E30 | Control board fault 3. The outdoor board reports a problem that may mean it needs replacing. | Technician repair |
| E31 | High leakage current. The control detected high leakage current on the high voltage side and stops the unit. | Technician repair |
| E32 | Outdoor board overheating. The outdoor control board keeps running too hot and the control has flagged it as a fault. The unit stops until the board cools and conditions allow it to restart. | Technician repair |
| E34 | Current spike. The board saw a sudden high current that suggests a possible short circuit, and stops the unit. | Technician repair |
| E35 | High current. The board detected a high current condition and stops the outdoor unit. | Technician repair |
| E36 | Startup error. Something abnormal happened while the compressor was starting, so the control aborted the start. The unit will try again, but repeated failures keep it from heating. | Technician repair |
| E37 | Control board fault 4. The outdoor board reports a fault that points to the board or the fan wiring. | Technician repair |
| E38 | Compressor voltage problem. The control found a voltage problem on the compressor circuit and stops it. | Technician repair |
| E39 | Control board fault 5. The outdoor board reports a fault that points to the board or its temperature sensors. | Technician repair |
| E40 | Compressor mismatch. The control's compressor settings do not match the compressor it is driving, so it will not run normally. | Technician repair |
| E41 | Low refrigerant. The control has detected a low refrigerant condition. | Technician repair |
| E42 | Low line voltage. The control sees the power supply voltage running low and protects the unit. | Often an owner fix |
| E43 | High line voltage. The control sees the power supply voltage running high and protects the unit. | Technician repair |
| E44 | Outside operating temperature range. The outdoor temperature is outside the range the unit is meant to run in. The unit may keep running normally. | Often an owner fix |
| E45 | Cooling test blocked. The cooling mode test could not start because the thermostat has indoor heat turned on. | Often an owner fix |
| E46 | Heating test blocked. The heating mode test could not start because indoor heat was switched on at the thermostat. | Often an owner fix |
| E47 | System verification test blocked. The startup system verification test could not run while the thermostat was calling for indoor heat. | Often an owner fix |
| E48 | Pump down blocked. Pump down mode, used by technicians to move refrigerant into the outdoor unit, could not start because indoor heat is on. | Often an owner fix |
| E49 | Charge mode blocked. Charging mode, used by technicians to adjust refrigerant, could not start because the thermostat has indoor heat on. | Often an owner fix |
| E50 | Control board voltage issue. There is a voltage problem on the outdoor control board itself. | Technician repair |
| E51 | Outdoor communication error. The outdoor board has detected trouble talking to the rest of the system over the communication wires. | Technician repair |
| Eb0 | No indoor airflow. The indoor unit reports airflow close to zero, so the heat pump cannot move heat into the house. The outdoor unit flags the fault and will not run normally. | Technician repair |
| Eb9 | Low indoor airflow. The indoor blower is moving less air than the system needs. The heat pump can keep running, but heating output and efficiency drop until the airflow problem is fixed. | Technician repair |
| Ed0 | No setup data. The control board lacks the model data it needs to run as part of a communicating system. | Technician repair |
| Ed1 | Invalid setup data. The control board's model data is invalid or does not suit the board. | Technician repair |
| Ed2 | Invalid system match. The outdoor unit needs more airflow than the indoor unit can deliver, so the pairing does not work as set up. | Technician repair |
| Ed3 | Invalid configuration. The model data does not match the control's actual hardware. | Technician repair |
| Ed4 | Data loader rejected. Data from the Bluetooth shared data loader was rejected by the control. | Technician repair |
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Heat pump not heating troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Goodman, *SZV9 Heat Pump Installation & Service Reference (IOG-4042) mobile.goodmanmfg.com
- Noritz, How to troubleshoot a tankless water heater noritz.com
- U.S. Department of Energy, Energy Saver: Air Conditioner Maintenance (archived June 14, 2026) web.archive.org
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Sears Home Services, Water heater problems and troubleshooting searshomeservices.com