Goodman two-stage gas furnace error codes
Goodman two-stage gas furnace code b3: blower in a limiting condition
The blower motor has hit a power, temperature or speed limit and is cutting back. The furnace keeps running but delivers less air than it should.

On this page
- Code
- b3
- Equipment
- Goodman two-stage gas furnace
- Models
- GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed
- What to do
- Often an owner fix
What code b3 means
Goodman's Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) lists b3 as blower in a limiting condition, for the GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed. A dual seven-segment LED display on the control board shows a two-character code such as E3 or b9. A ComfortNet communicating thermostat also shows a Call for Service icon and a short fault message.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- Clogged filters.
- Restrictive ductwork or closed registers.
- Ductwork that is too small.
- High temperatures around the furnace.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
- Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code b3 (the manual's first suspect is clogged filters). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Goodman codes
Other Goodman two-stage gas furnace codes
The full Goodman two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Goodman, Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) mobile.goodmanmfg.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com