Goodman two-stage gas furnace error codes

Goodman two-stage gas furnace code E3: limit or rollout open

The primary limit, auxiliary limit or rollout limit has opened, meaning the furnace overheated or flame left the burner area. The burner shuts off and the house blower keeps running.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
E3
Equipment
Goodman two-stage gas furnace
Models
GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed
What to do
Turn it off and call a pro

What code E3 means

Goodman's Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) lists E3 as limit or rollout open, for the GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed. A dual seven-segment LED display on the control board shows a two-character code such as E3 or b9. A ComfortNet communicating thermostat also shows a Call for Service icon and a short fault message.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • Too little air over the heat exchanger: a blocked filter, restrictive ducts, the wrong blower speed or a failed blower motor.
  • Flame rollout from misaligned burners.
  • A blocked flue or intake pipe, or a failed inducer.
  • Loose or wrongly connected wiring.

What you can safely check

  1. Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
  2. Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
  3. Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
  4. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E3 (the manual's first suspect is too little air over the heat exchanger: a blocked filter, restrictive ducts, the wrong blower speed or a failed blower motor). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman two-stage gas furnace codes

The full Goodman two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.