Goodman two-stage gas furnace code E7: igniter fault

The control found a fault in the igniter circuit when it tried to start a heating cycle, so the furnace stops and does not light.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
E7
Equipment
Goodman two-stage gas furnace
Models
GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed
What to do
Technician repair

What code E7 means

Goodman's Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) lists E7 as igniter fault, for the GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed. A dual seven-segment LED display on the control board shows a two-character code such as E3 or b9. A ComfortNet communicating thermostat also shows a Call for Service icon and a short fault message.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • The igniter is badly connected.
  • The igniter is shorted.
  • Poor unit ground.
  • A failed igniter relay on the control board.

What you can safely check

  1. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  2. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E7 (the manual's first suspect is the igniter is badly connected). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman two-stage gas furnace codes

The full Goodman two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.