Goodman two-stage gas furnace error codes
Goodman two-stage gas furnace code E9: high fire pressure switch did not close
When the furnace tries to move to high fire, the high stage pressure switch does not close. The furnace keeps heating on low fire only.

On this page
- Code
- E9
- Equipment
- Goodman two-stage gas furnace
- Models
- GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed
- What to do
- Turn it off and call a pro
What code E9 means
Goodman's Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) lists E9 as high fire pressure switch did not close, for the GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed. A dual seven-segment LED display on the control board shows a two-character code such as E3 or b9. A ComfortNet communicating thermostat also shows a Call for Service icon and a short fault message.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- The pressure switch hose is blocked, pinched or misconnected.
- A blocked exhaust or intake pipe, a plugged drain system or a weak inducer.
- The pressure switch set point is wrong or its contacts are faulty.
- Loose or wrongly connected wiring.
What you can safely check
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E9 (the manual's first suspect is the pressure switch hose is blocked, pinched or misconnected). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.