Goodman two-stage gas furnace error codes

Goodman two-stage gas furnace code E0: ignition lockout

The furnace failed to light, or lost flame, three times during one call for heat and has locked out. It sits idle for an hour before trying again unless it is reset sooner.

Photograph of a plain closed furnace cabinet with a metal duct in a tidy, softly lit basement
On this page
Code
E0
Equipment
Goodman two-stage gas furnace
Models
GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed
What to do
Technician repair

What code E0 means

Goodman's Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) lists E0 as ignition lockout, for the GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed. A dual seven-segment LED display on the control board shows a two-character code such as E3 or b9. A ComfortNet communicating thermostat also shows a Call for Service icon and a short fault message.

What usually causes it

The manual points to these causes for this code, roughly in the order a technician would rule them out:

  • No gas reaching the burners.
  • The front cover pressure switch is stuck open, often from a hose, wiring or drain issue.
  • A bad or misaligned igniter, or wrong orifices.
  • A coated, oxidized or badly connected flame sensor.
  • Flame lost after lighting from a gas interruption, wrong gas pressure, or a restricted flue or intake pipe.
  • A weak inducer.

What you can safely check

  1. Check that gas is reaching the house. If other gas appliances (stove, dryer) also do not work, the problem is the gas supply, so call your gas utility. Do not try to light anything or adjust the gas valve yourself.
  2. Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
  3. Look at the condensate drain. Condensing equipment makes water that drains through a small hose or trap. A kinked hose, a full pump or water pooling under the unit can make it shut down. Straighten a kinked hose and empty a full pump reservoir; leave the trap itself to a technician.
  4. Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
  5. Reset it once. Turn the unit off at its switch, wait a minute, and turn it back on, or use the reset the manual describes. One reset clears a passing glitch. If the same code comes back, stop resetting and book a technician.

When to call a technician

Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code E0 (the manual's first suspect is no gas reaching the burners). That saves a diagnostic visit from starting at zero.

Step by step for this kind of problem

The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.

Other Goodman two-stage gas furnace codes

The full Goodman two-stage gas furnace code table lists every code with its meaning, and explains how to read and clear them.

Sources

  1. Goodman, Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) mobile.goodmanmfg.com