Goodman two-stage gas furnace error codes: what each one means
Goodman's manual for the GMVC96, GCVC96, AMVC96 and ACVC96 two-stage variable-speed lists 24 codes. A dual seven-segment LED display on the control board shows a two-character code such as E3 or b9. A ComfortNet communicating thermostat also shows a Call for Service icon and a short fault message.

On this page
- Codes listed
- 24
- Turn off and call a pro
- 4
- Often an owner fix
- 4
How to read the code
The display is on the integrated control module behind the furnace doors. In normal use it shows On, or a status such as L0 or HI for low or high fire, and while running it can alternate with the airflow in hundreds of CFM. Fault codes start with E for burner and safety faults, b for the variable-speed blower motor, and d for missing or bad setup data.
The board remembers the last six faults. With the thermostat idle, holding the fault recall button for more than two seconds plays them back from newest to oldest.
An E0 lockout follows three failed tries to light during one heating call. The board resets itself after one hour, or sooner if power is turned off and on or the thermostat is turned down for a few seconds and set back. If the cause is still there, it locks out again.
With a ComfortNet thermostat, most faults also scroll the message Check Furnace. A blown 3 amp control fuse is the exception: the thermostat shows Battery Power instead because the furnace has lost its 24 volt supply.
Goodman two-stage gas furnace code table
Codes with a link have their own page with causes and the checks that fit that code.
| Code | What it means | What to do |
|---|---|---|
| On | Normal operation. The display shows On when the furnace is powered and sees no fault. | Often an owner fix |
| E0 | Ignition lockout. The furnace failed to light, or lost flame, three times during one call for heat and has locked out. It sits idle for an hour before trying again unless it is reset sooner. | Technician repair |
| E1 | Low fire pressure switch closed too early. The low stage pressure switch reads closed at the start of a heating call before the inducer has proved draft, so the furnace will not light. | Technician repair |
| E2 | Low fire pressure switch did not close. The inducer is running but the low stage pressure switch has not closed, so the control cannot confirm the vent is clear. The inducer keeps running and the burners stay off. | Turn it off and call a pro |
| E3 | Limit or rollout open. The primary limit, auxiliary limit or rollout limit has opened, meaning the furnace overheated or flame left the burner area. The burner shuts off and the house blower keeps running. | Turn it off and call a pro |
| E4 | Flame where none should be. The control sees flame when there is no call for heat. It runs the inducer and house blower and will not start a normal cycle. | Turn it off and call a pro |
| E5 | Control fuse blown. The 3 amp fuse on the control board is open, so the furnace has no control power. A ComfortNet thermostat shows Battery Power. | Technician repair |
| E6 | Weak flame signal. The furnace is lighting and heating, but the flame sensor signal is low. It is an early warning that the furnace may start failing to light. | Technician repair |
| E7 | Igniter fault. The control found a fault in the igniter circuit when it tried to start a heating cycle, so the furnace stops and does not light. | Technician repair |
| E8 | High fire pressure switch closed too early. The high stage pressure switch is already closed at the start of a heating call. The furnace runs on low fire only and will not go to high fire. | Technician repair |
| E9 | High fire pressure switch did not close. When the furnace tries to move to high fire, the high stage pressure switch does not close. The furnace keeps heating on low fire only. | Turn it off and call a pro |
| EA | Reversed polarity. The 115 volt power to the furnace or control is wired backwards, and the furnace will not run. | Technician repair |
| EF | Auxiliary switch open. An auxiliary switch, such as an overflow float on the cooling coil drain pan, has opened because of high water. | Often an owner fix |
| d0 | No setup data. The control board holds no shared data for this furnace model, so it will not run until the data is loaded. | Technician repair |
| d4 | Invalid memory card data. The control rejected the data on the memory card, so the furnace may run differently than expected or not at all. | Technician repair |
| b0 | Blower motor not running. The house blower motor is not running when the control is asking for it, and the furnace stops. | Technician repair |
| b1 | Blower communication lost. The control board can no longer talk to the variable-speed blower motor, and the furnace stops. | Technician repair |
| b2 | Blower horsepower mismatch. The motor horsepower in the furnace's setup data does not match the blower motor that is installed, and the furnace will not run. | Technician repair |
| b3 | Blower in a limiting condition. The blower motor has hit a power, temperature or speed limit and is cutting back. The furnace keeps running but delivers less air than it should. | Often an owner fix |
| b4 | Blower current trip. The blower motor sensed high current or lost control of its rotor and shut down, so the furnace stops. | Technician repair |
| b5 | Blower locked rotor. The blower motor failed to start ten times in a row, and the furnace stops. | Technician repair |
| b6 | Blower voltage or heat trip. The blower motor shut itself down because supply voltage was too high or low, or its power module overheated. | Technician repair |
| b7 | Blower missing parameters. The blower motor did not get the information it needs to run properly, and the furnace stops. | Technician repair |
| b9 | Low indoor airflow. The blower cannot move as much air as the control is asking for. The furnace runs with reduced output or stays on low fire when it should go to high. | Often an owner fix |
Codes that mean turn it off
These codes come from a flame, gas, venting or overheat safety. Leave the unit off and call a licensed technician rather than resetting it repeatedly:
Code by code
No code showing?
If the unit is not working and shows no code at all, start with the Furnace not working troubleshooter. It covers power, settings and supply problems that stop the control from running at all.
More error code tables
Sources
- Goodman, Installation Instructions for *CVC96 & *MVC96 Two-Stage Gas Furnace (IOG-2008A) mobile.goodmanmfg.com
- Carrier, Furnace not turning on (help page) carrier.com
- U.S. Consumer Product Safety Commission, Carbon Monoxide Information Center cpsc.gov
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov
- Noritz, How to troubleshoot a tankless water heater noritz.com