Carrier gas furnace code 13: limit lockout
Code 13.1: a switch in the main limit circuit stayed open for more than three minutes, so the control locked out gas heat. It tries again on its own after three hours.

On this page
- Code
- 13
- Equipment
- Carrier gas furnace
- Models
- 59SC2E single-stage 35-inch condensing gas furnaces
- What to do
- Turn it off and call a pro
What code 13 means
Carrier's 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) lists 13 as limit lockout, for the 59SC2E single-stage 35-inch condensing gas furnaces. A three-digit display on the control board shows codes such as 33.1, and the status light seen through the sight glass in the blower door flashes the first two digits as short and long flashes.
What usually causes it
The manual points to these causes for this code, roughly in the order a technician would rule them out:
- A dirty air filter or a restricted duct system.
- A loose blower wheel or a failing blower motor.
- A faulty limit switch or a bad connection.
- Gas input adjusted wrong.
- A tripped rollout switch from poor combustion air, wrong gas pressure or a venting fault.
What you can safely check
- Check the air filter. A clogged filter starves the system of air and can make a furnace overheat and shut itself down. Turn the furnace off, slide the filter out and hold it to the light; replace it if light barely passes through.
- Open the vents and clear the return grille. A furnace needs a free path for air: supply registers open in most rooms, and nothing (furniture, rugs, boxes) covering the large return grille. Too little airflow makes the heat exchanger run hot and trips the limit switch.
- Look at the vent pipes outside. High-efficiency furnaces, boilers and tankless heaters breathe through plastic pipes on an outside wall or the roof. From the ground, check that snow, ice, leaves or a nest are not blocking either opening, and clear what you can reach safely.
- Write the code down before you reset. Many controls forget the code once power is cut. Note it, how often it flashes, and when it happens. A technician can then go straight to the right part.
When to call a technician
Call if the code returns after one reset, if you saw or smelled anything unusual, or as soon as a check above points at a part inside the unit. Tell the technician the brand, the model number from the rating label, and that the control showed code 13 (the manual's first suspect is a dirty air filter or a restricted duct system). That saves a diagnostic visit from starting at zero.
Step by step for this kind of problem
The Furnace not working troubleshooter walks through the symptom question by question and ends with a clear next step.
Related Carrier codes
Other Carrier gas furnace codes
The full Carrier gas furnace code table lists every code with its meaning, and explains how to read and clear them.
Sources
- Carrier, 59SC2E Single-Stage 35-in. Tall 4-Way Multipoise High Efficiency Condensing Gas Furnace - Installation, Start-up, Operating and Service and Maintenance Instructions (59SC2E-03SI) shareddocs.com
- Carrier, Furnace not turning on (help page) carrier.com
- ENERGY STAR, Maintenance Checklist (heating and cooling) energystar.gov